Article: Skeletal stability after correction of maxillary hypoplasia by the Glasgow extra-oral distraction (GED) device

TitleSkeletal stability after correction of maxillary hypoplasia by the Glasgow extra-oral distraction (GED) device
Authors
KeywordsCleft palate
Distraction osteogenesis
Maxillary distraction
Osteotomy
Issue Date2006
PublisherChurchill Livingstone. The Journal's web site is located at http://www.elsevier.com/locate/bjom
Citation
British Journal Of Oral And Maxillofacial Surgery, 2006, v. 44 n. 4, p. 301-307 How to Cite?
AbstractMaxillary distraction osteogenesis delivers excellent results, particularly in patients with clefts. In the past, devices such as the conventional facemask and the rigid external distraction device have been used to correct maxillary hypoplasia after a Le Fort I osteotomy. We describe a new device, the Glasgow extra-oral distraction device. The extent of skeletal and dental stability of corrections achieved in 10 patients with maxillary hypoplasia associated with clefts was satisfactory. This device costs little, can be produced in developing countries, and provides effective treatment for severe secondary deformity associated with clefts. © 2005 The British Association of Oral and Maxillofacial Surgeons.
Persistent Identifierhttp://hdl.handle.net/10722/174210
ISSN
2021 Impact Factor: 2.018
2020 SCImago Journal Rankings: 0.793
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorJayade, CVen_US
dc.contributor.authorAyoub, AFen_US
dc.contributor.authorKhambay, BSen_US
dc.contributor.authorWalker, FSen_US
dc.contributor.authorGopalakrishnan, Ken_US
dc.contributor.authorMalik, NAen_US
dc.contributor.authorSrivastava, Den_US
dc.contributor.authorPradhan, Ren_US
dc.date.accessioned2012-11-22T01:58:35Z-
dc.date.available2012-11-22T01:58:35Z-
dc.date.issued2006en_US
dc.identifier.citationBritish Journal Of Oral And Maxillofacial Surgery, 2006, v. 44 n. 4, p. 301-307en_US
dc.identifier.issn0266-4356en_US
dc.identifier.urihttp://hdl.handle.net/10722/174210-
dc.description.abstractMaxillary distraction osteogenesis delivers excellent results, particularly in patients with clefts. In the past, devices such as the conventional facemask and the rigid external distraction device have been used to correct maxillary hypoplasia after a Le Fort I osteotomy. We describe a new device, the Glasgow extra-oral distraction device. The extent of skeletal and dental stability of corrections achieved in 10 patients with maxillary hypoplasia associated with clefts was satisfactory. This device costs little, can be produced in developing countries, and provides effective treatment for severe secondary deformity associated with clefts. © 2005 The British Association of Oral and Maxillofacial Surgeons.en_US
dc.languageengen_US
dc.publisherChurchill Livingstone. The Journal's web site is located at http://www.elsevier.com/locate/bjomen_US
dc.relation.ispartofBritish Journal of Oral and Maxillofacial Surgeryen_US
dc.subjectCleft palate-
dc.subjectDistraction osteogenesis-
dc.subjectMaxillary distraction-
dc.subjectOsteotomy-
dc.subject.meshAdulten_US
dc.subject.meshCephalometryen_US
dc.subject.meshCleft Palate - Radiography - Surgeryen_US
dc.subject.meshHumansen_US
dc.subject.meshMaxilla - Abnormalities - Radiography - Surgeryen_US
dc.subject.meshOsteogenesis, Distraction - Instrumentationen_US
dc.subject.meshOsteotomy, Le Fort - Adverse Effects - Methodsen_US
dc.subject.meshReproducibility Of Resultsen_US
dc.subject.meshTreatment Outcomeen_US
dc.titleSkeletal stability after correction of maxillary hypoplasia by the Glasgow extra-oral distraction (GED) deviceen_US
dc.typeArticleen_US
dc.identifier.emailKhambay, BS: bkhambay@hku.hken_US
dc.identifier.authorityKhambay, BS=rp01691en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1016/j.bjoms.2005.07.005en_US
dc.identifier.pmid16162377-
dc.identifier.scopuseid_2-s2.0-33745272542en_US
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-33745272542&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume44en_US
dc.identifier.issue4en_US
dc.identifier.spage301en_US
dc.identifier.epage307en_US
dc.identifier.isiWOS:000239640100008-
dc.publisher.placeUnited Kingdomen_US
dc.identifier.scopusauthoridJayade, CV=14019738200en_US
dc.identifier.scopusauthoridAyoub, AF=7005361507en_US
dc.identifier.scopusauthoridKhambay, BS=7003979053en_US
dc.identifier.scopusauthoridWalker, FS=14020710600en_US
dc.identifier.scopusauthoridGopalakrishnan, K=14019273500en_US
dc.identifier.scopusauthoridMalik, NA=55432373600en_US
dc.identifier.scopusauthoridSrivastava, D=9433539700en_US
dc.identifier.scopusauthoridPradhan, R=7005818925en_US
dc.identifier.issnl0266-4356-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats