Article: Modification of an adult-sized ahmed glaucoma valve for a small globe
Title | Modification of an adult-sized ahmed glaucoma valve for a small globe |
---|---|
Authors | |
Keywords | Ahmed valve glaucoma implant Glaucoma Small globe |
Issue Date | 2006 |
Publisher | Springer Japan. The Journal's web site is located at http://www.springeronline.com/sgw/cda/frontpage/0,11855,5-10074-70-18952714-0,00.html |
Citation | Japanese Journal Of Ophthalmology, 2006, v. 50 n. 1, p. 67-68 How to Cite? |
Persistent Identifier | http://hdl.handle.net/10722/176441 |
ISSN | 2023 Impact Factor: 2.1 2023 SCImago Journal Rankings: 0.907 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Law, RWK | en_US |
dc.contributor.author | Li, RTH | en_US |
dc.contributor.author | Lai, JSM | en_US |
dc.contributor.author | Rao, SK | en_US |
dc.contributor.author | Lam, DSC | en_US |
dc.date.accessioned | 2012-11-26T09:11:18Z | - |
dc.date.available | 2012-11-26T09:11:18Z | - |
dc.date.issued | 2006 | en_US |
dc.identifier.citation | Japanese Journal Of Ophthalmology, 2006, v. 50 n. 1, p. 67-68 | en_US |
dc.identifier.issn | 0021-5155 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/176441 | - |
dc.language | eng | en_US |
dc.publisher | Springer Japan. The Journal's web site is located at http://www.springeronline.com/sgw/cda/frontpage/0,11855,5-10074-70-18952714-0,00.html | en_US |
dc.relation.ispartof | Japanese Journal of Ophthalmology | en_US |
dc.subject | Ahmed valve glaucoma implant | - |
dc.subject | Glaucoma | - |
dc.subject | Small globe | - |
dc.subject.mesh | Chronic Disease | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Glaucoma Drainage Implants | en_US |
dc.subject.mesh | Glaucoma, Angle-Closure - Surgery | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Intraocular Pressure | en_US |
dc.subject.mesh | Middle Aged | en_US |
dc.subject.mesh | Prosthesis Implantation - Methods | en_US |
dc.title | Modification of an adult-sized ahmed glaucoma valve for a small globe | en_US |
dc.type | Article | en_US |
dc.identifier.email | Lai, JSM: laism@hku.hk | en_US |
dc.identifier.authority | Lai, JSM=rp00295 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1007/s10384-005-0265-1 | en_US |
dc.identifier.pmid | 16453192 | - |
dc.identifier.scopus | eid_2-s2.0-32044463351 | en_US |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-32044463351&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 50 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.spage | 67 | en_US |
dc.identifier.epage | 68 | en_US |
dc.identifier.isi | WOS:000235958700013 | - |
dc.publisher.place | Japan | en_US |
dc.identifier.scopusauthorid | Law, RWK=7201503302 | en_US |
dc.identifier.scopusauthorid | Li, RTH=8054515600 | en_US |
dc.identifier.scopusauthorid | Lai, JSM=7401939748 | en_US |
dc.identifier.scopusauthorid | Rao, SK=7404179059 | en_US |
dc.identifier.scopusauthorid | Lam, DSC=35500200200 | en_US |
dc.customcontrol.immutable | csl 140520 | - |
dc.identifier.issnl | 0021-5155 | - |