File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: A highly sensitive fluorimetric method for the determination of fluoride in biological material with Al 3+-calcein complex

TitleA highly sensitive fluorimetric method for the determination of fluoride in biological material with Al 3+-calcein complex
Authors
Issue Date2000
PublisherSpringer Verlag. The Journal's web site is located at http://link.springer.de/link/service/journals/00216/index.htm
Citation
Fresenius' Journal Of Analytical Chemistry, 2000, v. 368 n. 5, p. 501-504 How to Cite?
AbstractA highly sensitive fluorimetric method for the determination of fluoride was established. The method was based on quenching of the fluorescence of the Al 3+-calcein complex in CCl 3COOH-CH 3COOK buffer solution by fluoride. The fluorescence emission was measured at λ ex/λ em 480/503 nm, and the experimental variables and interference in this determination were studied. The linear calibration range was 0.8 ng/mL to 150 ng/mL and the detection limit was 0.2 ng/mL. The method was applied to determine fluoride in biological materials. The recovery was in the range of 96.3% to 104.7% and the relative standard deviation was 4.6%. The results obtained from the certified reference material by the present method agreed with the certified values. © Springer-Verlag 2000.
Persistent Identifierhttp://hdl.handle.net/10722/178714
ISSN
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorLi, HBen_US
dc.contributor.authorChen, Fen_US
dc.date.accessioned2012-12-19T09:49:17Z-
dc.date.available2012-12-19T09:49:17Z-
dc.date.issued2000en_US
dc.identifier.citationFresenius' Journal Of Analytical Chemistry, 2000, v. 368 n. 5, p. 501-504en_US
dc.identifier.issn0937-0633en_US
dc.identifier.urihttp://hdl.handle.net/10722/178714-
dc.description.abstractA highly sensitive fluorimetric method for the determination of fluoride was established. The method was based on quenching of the fluorescence of the Al 3+-calcein complex in CCl 3COOH-CH 3COOK buffer solution by fluoride. The fluorescence emission was measured at λ ex/λ em 480/503 nm, and the experimental variables and interference in this determination were studied. The linear calibration range was 0.8 ng/mL to 150 ng/mL and the detection limit was 0.2 ng/mL. The method was applied to determine fluoride in biological materials. The recovery was in the range of 96.3% to 104.7% and the relative standard deviation was 4.6%. The results obtained from the certified reference material by the present method agreed with the certified values. © Springer-Verlag 2000.en_US
dc.languageengen_US
dc.publisherSpringer Verlag. The Journal's web site is located at http://link.springer.de/link/service/journals/00216/index.htmen_US
dc.relation.ispartofFresenius' Journal of Analytical Chemistryen_US
dc.titleA highly sensitive fluorimetric method for the determination of fluoride in biological material with Al 3+-calcein complexen_US
dc.typeArticleen_US
dc.identifier.emailChen, F: sfchen@hku.hken_US
dc.identifier.authorityChen, F=rp00672en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1007/s002160000478-
dc.identifier.pmid11227533-
dc.identifier.scopuseid_2-s2.0-0034330348en_US
dc.identifier.hkuros61520-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0034330348&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume368en_US
dc.identifier.issue5en_US
dc.identifier.spage501en_US
dc.identifier.epage504en_US
dc.identifier.isiWOS:000165143700014-
dc.publisher.placeGermanyen_US
dc.identifier.scopusauthoridLi, HB=36066773900en_US
dc.identifier.scopusauthoridChen, F=7404907980en_US
dc.identifier.issnl0937-0633-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats