Conference Paper: Tests of Concrete-filled High Strength Steel Tubular X-joints under Compression
Title | Tests of Concrete-filled High Strength Steel Tubular X-joints under Compression |
---|---|
Authors | |
Issue Date | 2017 |
Publisher | CRC Press. |
Citation | Tubular Structures XVI: Proceedings of the 16th International Symposium on Tubular Structures (ISTS), Melbourne, Australia, 4-6 December 2017, p. 137-143 How to Cite? |
Abstract | This paper presents a test program of concrete-filled high strength steel tubular X-joints. The high strength steel tubes were cold-formed into square and rectangular hollow sections with nominal steel grades of 700 and 900 MPa. The cold-formed high strength steel tubes were infilled with normal and high strength concrete with nominal concrete grades of 35 and 100 MPa, respectively. A total of 15 tests was carried out covering chord sidewall slenderness ratios ranged from 12.6 to 40.6. In order to avoid failure of brace members and reveal the true capacity of the X-joint specimens, steel bearing plates were used to simulate the brace members. The test strengths were compared with the nominal strengths calculated using CIDECT design provisions. Overall, the nominal strengths predicted by the CIDECT design provisions are quite conservative for the concrete-filled high strength steel square and rectangular hollow section X-joints. |
Persistent Identifier | http://hdl.handle.net/10722/259850 |
ISBN |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Li, HT | - |
dc.contributor.author | Young, B | - |
dc.date.accessioned | 2018-09-03T04:15:02Z | - |
dc.date.available | 2018-09-03T04:15:02Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | Tubular Structures XVI: Proceedings of the 16th International Symposium on Tubular Structures (ISTS), Melbourne, Australia, 4-6 December 2017, p. 137-143 | - |
dc.identifier.isbn | 978-0815381341 | - |
dc.identifier.uri | http://hdl.handle.net/10722/259850 | - |
dc.description.abstract | This paper presents a test program of concrete-filled high strength steel tubular X-joints. The high strength steel tubes were cold-formed into square and rectangular hollow sections with nominal steel grades of 700 and 900 MPa. The cold-formed high strength steel tubes were infilled with normal and high strength concrete with nominal concrete grades of 35 and 100 MPa, respectively. A total of 15 tests was carried out covering chord sidewall slenderness ratios ranged from 12.6 to 40.6. In order to avoid failure of brace members and reveal the true capacity of the X-joint specimens, steel bearing plates were used to simulate the brace members. The test strengths were compared with the nominal strengths calculated using CIDECT design provisions. Overall, the nominal strengths predicted by the CIDECT design provisions are quite conservative for the concrete-filled high strength steel square and rectangular hollow section X-joints. | - |
dc.language | eng | - |
dc.publisher | CRC Press. | - |
dc.relation.ispartof | Tubular Structures XVI: Proceedings of the 16th International Symposium on Tubular Structures, 2017 | - |
dc.title | Tests of Concrete-filled High Strength Steel Tubular X-joints under Compression | - |