File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Volumetric measurements of lung nodules with multi-detector row CT: Effect of changes in lung volume

TitleVolumetric measurements of lung nodules with multi-detector row CT: Effect of changes in lung volume
Authors
KeywordsComputed tomography (CT), multi-detector row
Computed tomography (CT), quantitative
Computed tomography (CT), three-dimensional
Computers, diagnostic aid
Lung, nodule
Issue Date2006
Citation
Korean Journal of Radiology, 2006, v. 7, n. 4, p. 243-248 How to Cite?
AbstractObjective: To evaluate how changes in lung volume affect volumetric measurements of lung nodules using a multi-detector row CT. Materials and Methods: Ten subjects with asthma or chronic bronchitis who had one or more lung nodules were included. For each subject, two sets of CT images were obtained at inspiration and at expiration. A total of 33 nodules (23 nodules ≥ 3 mm) were identified and their volume measured using a semiautomatic volume measurement program. Differences between nodule volume on inspiration and expiration were compared using the paired t-test. Percent differences, between on inspiration and expiration, in nodule attenuation, total lung volume, whole lung attenuation, and regional lung attenuation, were computed and compared with percent difference in nodule volume determined by linear correlation analysis. Results: The difference in nodule volume observed between inspiration and expiration was significant (p < 0.01); the mean percent difference in lung nodule volume was 23.1 % for all nodules and for nodules ≥ 3 mm. The volume of nodules was measured to be larger on expiration CT than on inspiration CT (28 out of 33 nodules; 19 out of 23 nodules ≥ 3 mm). A statistically significant correlation was found between the percent difference of lung nodule volume and lung volume or regional lung attenuation (p < 0.05) for nodules ≥ 3 mm. Conclusion: Volumetric measurements of pulmonary nodules were significantly affected by changes in lung volume. The variability in this respiration-related measurement should be considered to determine whether growth has occurred in a lung nodule.
Persistent Identifierhttp://hdl.handle.net/10722/315978
ISSN
2021 Impact Factor: 7.109
2020 SCImago Journal Rankings: 1.080
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorGoo, Jin Mo-
dc.contributor.authorKim, Kwang Gi-
dc.contributor.authorGierada, David S.-
dc.contributor.authorCastro, Mario-
dc.contributor.authorBae, Kyongtae T.-
dc.date.accessioned2022-08-24T15:48:48Z-
dc.date.available2022-08-24T15:48:48Z-
dc.date.issued2006-
dc.identifier.citationKorean Journal of Radiology, 2006, v. 7, n. 4, p. 243-248-
dc.identifier.issn1229-6929-
dc.identifier.urihttp://hdl.handle.net/10722/315978-
dc.description.abstractObjective: To evaluate how changes in lung volume affect volumetric measurements of lung nodules using a multi-detector row CT. Materials and Methods: Ten subjects with asthma or chronic bronchitis who had one or more lung nodules were included. For each subject, two sets of CT images were obtained at inspiration and at expiration. A total of 33 nodules (23 nodules ≥ 3 mm) were identified and their volume measured using a semiautomatic volume measurement program. Differences between nodule volume on inspiration and expiration were compared using the paired t-test. Percent differences, between on inspiration and expiration, in nodule attenuation, total lung volume, whole lung attenuation, and regional lung attenuation, were computed and compared with percent difference in nodule volume determined by linear correlation analysis. Results: The difference in nodule volume observed between inspiration and expiration was significant (p < 0.01); the mean percent difference in lung nodule volume was 23.1 % for all nodules and for nodules ≥ 3 mm. The volume of nodules was measured to be larger on expiration CT than on inspiration CT (28 out of 33 nodules; 19 out of 23 nodules ≥ 3 mm). A statistically significant correlation was found between the percent difference of lung nodule volume and lung volume or regional lung attenuation (p < 0.05) for nodules ≥ 3 mm. Conclusion: Volumetric measurements of pulmonary nodules were significantly affected by changes in lung volume. The variability in this respiration-related measurement should be considered to determine whether growth has occurred in a lung nodule.-
dc.languageeng-
dc.relation.ispartofKorean Journal of Radiology-
dc.subjectComputed tomography (CT), multi-detector row-
dc.subjectComputed tomography (CT), quantitative-
dc.subjectComputed tomography (CT), three-dimensional-
dc.subjectComputers, diagnostic aid-
dc.subjectLung, nodule-
dc.titleVolumetric measurements of lung nodules with multi-detector row CT: Effect of changes in lung volume-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.3348/kjr.2006.7.4.243-
dc.identifier.pmid17143027-
dc.identifier.scopuseid_2-s2.0-33845459604-
dc.identifier.volume7-
dc.identifier.issue4-
dc.identifier.spage243-
dc.identifier.epage248-
dc.identifier.eissn1229-6929-
dc.identifier.isiWOS:000243313500004-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats