Article: Effects of CT Section Thickness and Reconstruction Kernel on Emphysema Quantification. Relationship to the Magnitude of the CT Emphysema Index

TitleEffects of CT Section Thickness and Reconstruction Kernel on Emphysema Quantification. Relationship to the Magnitude of the CT Emphysema Index
Authors
Keywordscomputed tomography
Emphysema
histology
Issue Date2010
Citation
Academic Radiology, 2010, v. 17, n. 2, p. 146-156 How to Cite?
AbstractRationale and Objectives: Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether their effects are related to the magnitude of the measurement. Materials and Methods: Low-radiation-dose multidetector CT was performed in 21 subjects representing a wide range of emphysema severity. Images were reconstructed using 20 different combinations of section thickness and reconstruction kernel. Emphysema index values were determined as the percentage of lung pixels having attenuation lower than multiple thresholds ranging from -960 HU to -890 HU. The index values obtained from the different thickness-kernel combinations were compared by repeated measures analysis of variance and Bland-Altman plots of mean versus difference in all subjects, and correlated with quantitative histology (mean linear intercept, Lm) in a subset of resected lung specimens. Results: The effects of section thickness and reconstruction kernel on the emphysema index were significant (P < .001) and diminished as the index attenuation threshold was raised. The changes in index values from changing the thickness-kernel combination were largest for subjects with intermediate index values (10%-30%), and became progressively smaller for those with lower and higher index values. This pattern was consistent regardless of the thickness-kernel combinations compared and the HU threshold used. Correlations between the emphysema index values obtained with each thickness-kernel combination and Lm ranged from r = 0.55-0.68 (P = .007-.03). Conclusion: The effects of CT section thickness and kernel on emphysema index values varied systematically with the magnitude of the emphysema index. All reconstruction techniques provided significant correlations with quantitative histology. © 2010 AUR.
Persistent Identifierhttp://hdl.handle.net/10722/316027
ISSN
2021 Impact Factor: 5.482
2020 SCImago Journal Rankings: 0.986
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorGierada, David S.-
dc.contributor.authorBierhals, Andrew J.-
dc.contributor.authorChoong, Cliff K.-
dc.contributor.authorBartel, Seth T.-
dc.contributor.authorRitter, Jon H.-
dc.contributor.authorDas, Nitin A.-
dc.contributor.authorHong, Cheng-
dc.contributor.authorPilgram, Thomas K.-
dc.contributor.authorBae, Kyongtae T.-
dc.contributor.authorWhiting, Bruce R.-
dc.contributor.authorWoods, Jason C.-
dc.contributor.authorHogg, James C.-
dc.contributor.authorLutey, Barbara A.-
dc.contributor.authorBattafarano, Richard J.-
dc.contributor.authorCooper, Joel D.-
dc.contributor.authorMeyers, Bryan F.-
dc.contributor.authorPatterson, G. Alexander-
dc.date.accessioned2022-08-24T15:48:59Z-
dc.date.available2022-08-24T15:48:59Z-
dc.date.issued2010-
dc.identifier.citationAcademic Radiology, 2010, v. 17, n. 2, p. 146-156-
dc.identifier.issn1076-6332-
dc.identifier.urihttp://hdl.handle.net/10722/316027-
dc.description.abstractRationale and Objectives: Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether their effects are related to the magnitude of the measurement. Materials and Methods: Low-radiation-dose multidetector CT was performed in 21 subjects representing a wide range of emphysema severity. Images were reconstructed using 20 different combinations of section thickness and reconstruction kernel. Emphysema index values were determined as the percentage of lung pixels having attenuation lower than multiple thresholds ranging from -960 HU to -890 HU. The index values obtained from the different thickness-kernel combinations were compared by repeated measures analysis of variance and Bland-Altman plots of mean versus difference in all subjects, and correlated with quantitative histology (mean linear intercept, Lm) in a subset of resected lung specimens. Results: The effects of section thickness and reconstruction kernel on the emphysema index were significant (P < .001) and diminished as the index attenuation threshold was raised. The changes in index values from changing the thickness-kernel combination were largest for subjects with intermediate index values (10%-30%), and became progressively smaller for those with lower and higher index values. This pattern was consistent regardless of the thickness-kernel combinations compared and the HU threshold used. Correlations between the emphysema index values obtained with each thickness-kernel combination and Lm ranged from r = 0.55-0.68 (P = .007-.03). Conclusion: The effects of CT section thickness and kernel on emphysema index values varied systematically with the magnitude of the emphysema index. All reconstruction techniques provided significant correlations with quantitative histology. © 2010 AUR.-
dc.languageeng-
dc.relation.ispartofAcademic Radiology-
dc.subjectcomputed tomography-
dc.subjectEmphysema-
dc.subjecthistology-
dc.titleEffects of CT Section Thickness and Reconstruction Kernel on Emphysema Quantification. Relationship to the Magnitude of the CT Emphysema Index-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.acra.2009.08.007-
dc.identifier.pmid19931472-
dc.identifier.scopuseid_2-s2.0-73049095694-
dc.identifier.volume17-
dc.identifier.issue2-
dc.identifier.spage146-
dc.identifier.epage156-
dc.identifier.isiWOS:000273834100004-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats