Article: Gadolinium as a CT contrast agent: Assessment in a porcine model

TitleGadolinium as a CT contrast agent: Assessment in a porcine model
Authors
KeywordsComputed tomography (CT), contrast enhancement
Computed tomography (CT), contrast media
Contrast media, experimental studies
Gadolinium
Issue Date1999
Citation
Radiology, 1999, v. 210, n. 3, p. 829-834 How to Cite?
AbstractPURPOSE: To investigate the use of gadolinium as a computed tomographic (CT) contrast agent. MATERIALS AND METHODS: In vitro attenuation measurements of multiple dilutions of gadodiamide and ioversol were compared. In three pigs, 50-mL boluses of undiluted gadodiamide were injected intravenously at 2 mL/sec, and repeated single-level scans were obtained through the lung bases, liver, and kidneys. The doses of 0.8-1.0 mmol of gadolinium per kilogram of body weight were approximately three times the highest doses currently used in patients. Enhancement was determined from attenuation measurements in the aorta, pulmonary arteries, liver, and kidneys. RESULTS: In vitro, the attenuation of undiluted gadodiamide (3,069 HU) was equivalent to that of ioversol diluted to 106 mg of iodine per milliliter and at equimolar concentrations was 50% greater than that of ioversol. The magnitude of and time to peak enhancement were 141 HU and 27 seconds (n = 3) for the aorta; 168 HU and 21 seconds (n = 3) for the pulmonary arteries; 23 HU and 65 seconds (n = 2) for the liver; and 63 HU and 32 seconds (n = 1) for the kidneys. Time-attenuation curves revealed a useful duration of enhancement of 20-30 seconds for the aorta arid pulmonary arteries. CONCLUSION: Gadolinium produces good vascular enhancement, adequate renal enhancement, and suboptimal hepatic enhancement. Further study is needed to determine the safety of the gadolinium dose required to produce similar enhancement in patients.
Persistent Identifierhttp://hdl.handle.net/10722/316153
ISSN
2021 Impact Factor: 29.146
2020 SCImago Journal Rankings: 3.118
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorGierada, David S.-
dc.contributor.authorBae, Kyongtae-
dc.date.accessioned2022-08-24T15:49:25Z-
dc.date.available2022-08-24T15:49:25Z-
dc.date.issued1999-
dc.identifier.citationRadiology, 1999, v. 210, n. 3, p. 829-834-
dc.identifier.issn0033-8419-
dc.identifier.urihttp://hdl.handle.net/10722/316153-
dc.description.abstractPURPOSE: To investigate the use of gadolinium as a computed tomographic (CT) contrast agent. MATERIALS AND METHODS: In vitro attenuation measurements of multiple dilutions of gadodiamide and ioversol were compared. In three pigs, 50-mL boluses of undiluted gadodiamide were injected intravenously at 2 mL/sec, and repeated single-level scans were obtained through the lung bases, liver, and kidneys. The doses of 0.8-1.0 mmol of gadolinium per kilogram of body weight were approximately three times the highest doses currently used in patients. Enhancement was determined from attenuation measurements in the aorta, pulmonary arteries, liver, and kidneys. RESULTS: In vitro, the attenuation of undiluted gadodiamide (3,069 HU) was equivalent to that of ioversol diluted to 106 mg of iodine per milliliter and at equimolar concentrations was 50% greater than that of ioversol. The magnitude of and time to peak enhancement were 141 HU and 27 seconds (n = 3) for the aorta; 168 HU and 21 seconds (n = 3) for the pulmonary arteries; 23 HU and 65 seconds (n = 2) for the liver; and 63 HU and 32 seconds (n = 1) for the kidneys. Time-attenuation curves revealed a useful duration of enhancement of 20-30 seconds for the aorta arid pulmonary arteries. CONCLUSION: Gadolinium produces good vascular enhancement, adequate renal enhancement, and suboptimal hepatic enhancement. Further study is needed to determine the safety of the gadolinium dose required to produce similar enhancement in patients.-
dc.languageeng-
dc.relation.ispartofRadiology-
dc.subjectComputed tomography (CT), contrast enhancement-
dc.subjectComputed tomography (CT), contrast media-
dc.subjectContrast media, experimental studies-
dc.subjectGadolinium-
dc.titleGadolinium as a CT contrast agent: Assessment in a porcine model-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1148/radiology.210.3.r99mr06829-
dc.identifier.pmid10207488-
dc.identifier.scopuseid_2-s2.0-0033044150-
dc.identifier.volume210-
dc.identifier.issue3-
dc.identifier.spage829-
dc.identifier.epage834-
dc.identifier.isiWOS:000078796500037-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats