File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Carotid stenting for irradiation-associated carotid stenosis 3 years after previous carotid endarterectomy

TitleCarotid stenting for irradiation-associated carotid stenosis 3 years after previous carotid endarterectomy
Authors
KeywordsCarotid stenosis
Radiotherapy, adverse effects
Stents
Ultrasonography, Doppler, Duplex
Issue Date2003
PublisherHong Kong Medical Association. The Journal's web site is located at http://www.hkmj.org/resources/supp.html
Citation
Hong Kong Medical Journal, 2003, v. 9 n. 1, p. 51-53 How to Cite?
AbstractExtracranial carotid stenosis is a known complication of external irradiation to the head and neck region. We report on a patient with previous carotid endarterectomy for irradiation-associated carotid stenosis. This patient developed symptomatic carotid stenosis over the ipsilateral common carotid artery proximal to the previous endarterectomy site 3 years later, and was successfully treated with carotid angioplasty and stenting. This case illustrates the importance of Duplex scan surveillance after carotid endarterectomy for patients with irradiation-associated carotid stenosis. The complimentary role of carotid endarterectomy and carotid angioplasty for managing such a patient is highlighted.
Persistent Identifierhttp://hdl.handle.net/10722/44682
ISSN
2021 Impact Factor: 1.256
2020 SCImago Journal Rankings: 0.357
References

 

DC FieldValueLanguage
dc.contributor.authorTing, ACWen_HK
dc.contributor.authorCheng, SWKen_HK
dc.contributor.authorCheng, PWen_HK
dc.date.accessioned2007-10-30T06:07:35Z-
dc.date.available2007-10-30T06:07:35Z-
dc.date.issued2003en_HK
dc.identifier.citationHong Kong Medical Journal, 2003, v. 9 n. 1, p. 51-53en_HK
dc.identifier.issn1024-2708en_HK
dc.identifier.urihttp://hdl.handle.net/10722/44682-
dc.description.abstractExtracranial carotid stenosis is a known complication of external irradiation to the head and neck region. We report on a patient with previous carotid endarterectomy for irradiation-associated carotid stenosis. This patient developed symptomatic carotid stenosis over the ipsilateral common carotid artery proximal to the previous endarterectomy site 3 years later, and was successfully treated with carotid angioplasty and stenting. This case illustrates the importance of Duplex scan surveillance after carotid endarterectomy for patients with irradiation-associated carotid stenosis. The complimentary role of carotid endarterectomy and carotid angioplasty for managing such a patient is highlighted.en_HK
dc.format.extent264267 bytes-
dc.format.extent2370 bytes-
dc.format.extent3563 bytes-
dc.format.mimetypeapplication/pdf-
dc.format.mimetypetext/plain-
dc.format.mimetypetext/plain-
dc.languageengen_HK
dc.publisherHong Kong Medical Association. The Journal's web site is located at http://www.hkmj.org/resources/supp.htmlen_HK
dc.relation.ispartofHong Kong Medical Journalen_HK
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectCarotid stenosisen_HK
dc.subjectRadiotherapy, adverse effectsen_HK
dc.subjectStentsen_HK
dc.subjectUltrasonography, Doppler, Duplexen_HK
dc.subject.meshCarotid Stenosis - etiology - radiography - surgery - therapyen_HK
dc.subject.meshEndarterectomy, Carotiden_HK
dc.subject.meshStentsen_HK
dc.subject.meshAngioplasty, Balloonen_HK
dc.subject.meshNasopharyngeal Neoplasms - radiotherapyen_HK
dc.titleCarotid stenting for irradiation-associated carotid stenosis 3 years after previous carotid endarterectomyen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1024-2708&volume=9&issue=1&spage=51&epage=53&date=2003&atitle=Carotid+stenting+for+irradiation-associated+carotid+stenosis+3+years+after+previous+carotid+endarterectomyen_HK
dc.identifier.emailCheng, SWK: wkcheng@hkucc.hku.hken_HK
dc.identifier.authorityCheng, SWK=rp00374en_HK
dc.description.naturepublished_or_final_versionen_HK
dc.identifier.pmid12547958-
dc.identifier.scopuseid_2-s2.0-0037308152en_HK
dc.identifier.hkuros82476-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0037308152&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume9en_HK
dc.identifier.issue1en_HK
dc.identifier.spage51en_HK
dc.identifier.epage53en_HK
dc.publisher.placeHong Kongen_HK
dc.identifier.scopusauthoridTing, ACW=7102858552en_HK
dc.identifier.scopusauthoridCheng, SWK=7404684779en_HK
dc.identifier.scopusauthoridCheng, PW=7401619084en_HK
dc.identifier.issnl1024-2708-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats