File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Custom-made titanium mandibular reconstruction tray

TitleCustom-made titanium mandibular reconstruction tray
Authors
KeywordsBone graft
Mandible
Reconstruction
Titanium
Issue Date1999
PublisherWiley-Blackwell Publishing Ltd.. The Journal's web site is located at http://www.wiley.com/bw/journal.asp?ref=0045-0421
Citation
Australian Dental Journal, 1999, v. 44 n. 3, p. 195-199 How to Cite?
AbstractReconstruction of the mandible after ablative surgery can be achieved by using preformed trays or trays formed from models produced by computer-assisted modelling systems. The former presents difficulty in matching the required facial contour, jaw relationship and condylar position; while the latter is expensive. This paper presents a simple and inexpensive method of fabricating a custom-made titanium bone grafting tray. The dimensions of the patient's mandible are obtained by clinical measurement. Such measurements are used to construct a mandibular replica. The region to be reconstructed is carved to produce the ideal shape and dimensions of an edentulous segment. The tray is made either by casting or by swaging. Twenty-one custom-made titanium bone grafting trays have been fitted in patients with encouraging results. This method of bone grafting tray construction is a simple, inexpensive technique for achieving excellent facial contour and functional reconstruction after mandibulectomy.
Persistent Identifierhttp://hdl.handle.net/10722/66156
ISSN
2021 Impact Factor: 2.259
2020 SCImago Journal Rankings: 0.701
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorSamman, Nen_HK
dc.contributor.authorLuk, WKen_HK
dc.contributor.authorChow, TWen_HK
dc.contributor.authorCheung, LKen_HK
dc.contributor.authorTideman, Hen_HK
dc.contributor.authorClark, RKFen_HK
dc.date.accessioned2010-09-06T05:44:02Z-
dc.date.available2010-09-06T05:44:02Z-
dc.date.issued1999en_HK
dc.identifier.citationAustralian Dental Journal, 1999, v. 44 n. 3, p. 195-199en_HK
dc.identifier.issn0045-0421en_HK
dc.identifier.urihttp://hdl.handle.net/10722/66156-
dc.description.abstractReconstruction of the mandible after ablative surgery can be achieved by using preformed trays or trays formed from models produced by computer-assisted modelling systems. The former presents difficulty in matching the required facial contour, jaw relationship and condylar position; while the latter is expensive. This paper presents a simple and inexpensive method of fabricating a custom-made titanium bone grafting tray. The dimensions of the patient's mandible are obtained by clinical measurement. Such measurements are used to construct a mandibular replica. The region to be reconstructed is carved to produce the ideal shape and dimensions of an edentulous segment. The tray is made either by casting or by swaging. Twenty-one custom-made titanium bone grafting trays have been fitted in patients with encouraging results. This method of bone grafting tray construction is a simple, inexpensive technique for achieving excellent facial contour and functional reconstruction after mandibulectomy.en_HK
dc.languageengen_HK
dc.publisherWiley-Blackwell Publishing Ltd.. The Journal's web site is located at http://www.wiley.com/bw/journal.asp?ref=0045-0421en_HK
dc.relation.ispartofAustralian Dental Journalen_HK
dc.subjectBone graft-
dc.subjectMandible-
dc.subjectReconstruction-
dc.subjectTitanium-
dc.subject.meshBone Transplantation - instrumentationen_HK
dc.subject.meshDental Alloysen_HK
dc.subject.meshDental Casting Techniqueen_HK
dc.subject.meshDental Modelsen_HK
dc.subject.meshEquipment Designen_HK
dc.subject.meshHumansen_HK
dc.subject.meshMandible - surgeryen_HK
dc.subject.meshReconstructive Surgical Procedures - instrumentationen_HK
dc.subject.meshTitaniumen_HK
dc.titleCustom-made titanium mandibular reconstruction trayen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0045-0421&volume=44&spage=195&epage=9&date=1999&atitle=Custom-made+titanium+mandibular+reconstruction+trayen_HK
dc.identifier.emailSamman, N:nsamman@hkucc.hku.hken_HK
dc.identifier.emailLuk, WK:wkluka@hkucc.hku.hken_HK
dc.identifier.emailChow, TW:twchow@hku.hken_HK
dc.identifier.emailCheung, LK:lkcheung@hkucc.hku.hken_HK
dc.identifier.authoritySamman, N=rp00021en_HK
dc.identifier.authorityLuk, WK=rp00008en_HK
dc.identifier.authorityChow, TW=rp00009en_HK
dc.identifier.authorityCheung, LK=rp00013en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1111/j.1834-7819.1999.tb00221.x-
dc.identifier.pmid10592564en_HK
dc.identifier.scopuseid_2-s2.0-0033191715en_HK
dc.identifier.hkuros51620en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0033191715&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume44en_HK
dc.identifier.issue3en_HK
dc.identifier.spage195en_HK
dc.identifier.epage199en_HK
dc.identifier.isiWOS:000082737400006-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridSamman, N=7006413627en_HK
dc.identifier.scopusauthoridLuk, WK=7006636056en_HK
dc.identifier.scopusauthoridChow, TW=7203012369en_HK
dc.identifier.scopusauthoridCheung, LK=7102302747en_HK
dc.identifier.scopusauthoridTideman, H=7005602469en_HK
dc.identifier.scopusauthoridClark, RKF=7406318698en_HK
dc.identifier.issnl0045-0421-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats