File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Microtensile bond strengths of glass ionomer (polyalkenoate) cements to dentine using four conditioners

TitleMicrotensile bond strengths of glass ionomer (polyalkenoate) cements to dentine using four conditioners
Authors
KeywordsChemicals And Cas Registry Numbers
Issue Date2000
PublisherElsevier Ltd. The Journal's web site is located at http://www.elsevier.com/locate/jdent
Citation
Journal Of Dentistry, 2000, v. 28 n. 5, p. 361-366 How to Cite?
AbstractObjectives: The purpose of this study was to measure the microtensile bond strengths of three glass ionomer cements to dentine (Photac-Fil Quick; Fuji II LC; Fuji IX GP) using four different conditioners (Ketac Conditioner; Dentin Conditioner; Cavity Conditioner; and an experimental conditioner, K-930). Methods: Superficial occlusal dentine of extracted human third molars was exposed, finished with wet 600-grit silicon carbide paper, and each of the above glass ionomer cements bonded using the four conditioners according to the manufacturers' instructions. After 24 h in tap water at 37°C, the teeth were sectioned to obtain 3-4 bar-shaped specimens. Ten specimens were prepared for each group and shaped to an hour-glass form of (1.2 ± 0.02) mm diameter. The specimens were mounted in ajig and stressed in tension at a crosshead speed of 1 mm/min until failure. The mean bond strengths were calculated and compared using one-way ANOVA and LSD tests, and the fracture modes were examined by scanning electron microscopy. Results: Mean microtensile bond strengths for Photac-Fil Quick were not significantly different from Fuji II LC for each of the conditioners used. However, the bond strengths for Photac-Fil Quick were significantly greater than Fuji II LC when no conditioner was applied. Mean microtensile bond strengths of conditioned specimens of Fuji II LC were significantly greater than non-conditioned specimens. Mean microtensile bond strengths of non-conditioned specimens of Fuji IX GP were not significantly different from conditioned specimens. The fracture mode of all specimens demonstrated mostly cohesive failure within the cement. Significance: The use of surface conditioners resulted in improvement in bond strength of Fuji II LC, while Photac-Fil Quick and Fuji IX GP showed no difference. © 2000 Elsevier Science Ltd. All rights reserved.
Persistent Identifierhttp://hdl.handle.net/10722/90589
ISSN
2021 Impact Factor: 4.991
2020 SCImago Journal Rankings: 1.504
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorTanumiharja, Men_HK
dc.contributor.authorBurrow, MFen_HK
dc.contributor.authorTyas, MJen_HK
dc.date.accessioned2010-09-17T10:05:20Z-
dc.date.available2010-09-17T10:05:20Z-
dc.date.issued2000en_HK
dc.identifier.citationJournal Of Dentistry, 2000, v. 28 n. 5, p. 361-366en_HK
dc.identifier.issn0300-5712en_HK
dc.identifier.urihttp://hdl.handle.net/10722/90589-
dc.description.abstractObjectives: The purpose of this study was to measure the microtensile bond strengths of three glass ionomer cements to dentine (Photac-Fil Quick; Fuji II LC; Fuji IX GP) using four different conditioners (Ketac Conditioner; Dentin Conditioner; Cavity Conditioner; and an experimental conditioner, K-930). Methods: Superficial occlusal dentine of extracted human third molars was exposed, finished with wet 600-grit silicon carbide paper, and each of the above glass ionomer cements bonded using the four conditioners according to the manufacturers' instructions. After 24 h in tap water at 37°C, the teeth were sectioned to obtain 3-4 bar-shaped specimens. Ten specimens were prepared for each group and shaped to an hour-glass form of (1.2 ± 0.02) mm diameter. The specimens were mounted in ajig and stressed in tension at a crosshead speed of 1 mm/min until failure. The mean bond strengths were calculated and compared using one-way ANOVA and LSD tests, and the fracture modes were examined by scanning electron microscopy. Results: Mean microtensile bond strengths for Photac-Fil Quick were not significantly different from Fuji II LC for each of the conditioners used. However, the bond strengths for Photac-Fil Quick were significantly greater than Fuji II LC when no conditioner was applied. Mean microtensile bond strengths of conditioned specimens of Fuji II LC were significantly greater than non-conditioned specimens. Mean microtensile bond strengths of non-conditioned specimens of Fuji IX GP were not significantly different from conditioned specimens. The fracture mode of all specimens demonstrated mostly cohesive failure within the cement. Significance: The use of surface conditioners resulted in improvement in bond strength of Fuji II LC, while Photac-Fil Quick and Fuji IX GP showed no difference. © 2000 Elsevier Science Ltd. All rights reserved.en_HK
dc.languageengen_HK
dc.publisherElsevier Ltd. The Journal's web site is located at http://www.elsevier.com/locate/jdenten_HK
dc.relation.ispartofJournal of Dentistryen_HK
dc.subjectChemicals And Cas Registry Numbersen_HK
dc.subject.meshAcrylic Resins - chemistryen_HK
dc.subject.meshAnalysis of Varianceen_HK
dc.subject.meshCarbon Compounds, Inorganicen_HK
dc.subject.meshDental Bonding - methodsen_HK
dc.subject.meshDentin - ultrastructureen_HK
dc.subject.meshDentin-Bonding Agents - chemistryen_HK
dc.subject.meshGlass Ionomer Cements - chemistryen_HK
dc.subject.meshHumansen_HK
dc.subject.meshMaterials Testingen_HK
dc.subject.meshMicroscopy, Electron, Scanningen_HK
dc.subject.meshMolar, Thirden_HK
dc.subject.meshResins, Synthetic - chemistryen_HK
dc.subject.meshSilicon Compoundsen_HK
dc.subject.meshStress, Mechanicalen_HK
dc.subject.meshSurface Propertiesen_HK
dc.subject.meshTensile Strengthen_HK
dc.subject.meshTime Factorsen_HK
dc.subject.meshWateren_HK
dc.titleMicrotensile bond strengths of glass ionomer (polyalkenoate) cements to dentine using four conditionersen_HK
dc.typeArticleen_HK
dc.identifier.emailBurrow, MF:mfburr58@hku.hken_HK
dc.identifier.authorityBurrow, MF=rp01306en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/S0300-5712(00)00009-9-
dc.identifier.pmid10785303-
dc.identifier.scopuseid_2-s2.0-0347053865en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0347053865&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume28en_HK
dc.identifier.issue5en_HK
dc.identifier.spage361en_HK
dc.identifier.epage366en_HK
dc.identifier.isiWOS:000086941300010-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridTanumiharja, M=6602267792en_HK
dc.identifier.scopusauthoridBurrow, MF=7005876730en_HK
dc.identifier.scopusauthoridTyas, MJ=7006088443en_HK
dc.identifier.issnl0300-5712-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats