Conference Paper: Tests of T-joints in RHS and SHS high strength stainless steel tubes

TitleTests of T-joints in RHS and SHS high strength stainless steel tubes
Authors
Issue Date2007
Citation
5Th International Conference On Advances In Steel Structures, Icass 2007, 2007, v. 3, p. 563-570 How to Cite?
AbstractThis paper describes a test program on a wide range of cold-formed stainless steel welded tubular Tjoints fabricated from square hollow section and rectangular hollow section brace and chord members. A total of 15 tests was performed. High strength stainless steel (duplex and high strength austenitic) specimens were tested. The tests were performed by supporting the chord member of the specimen along its entire length with the pure concentrated force applied to the brace member. The ratio of brace width to chord width (β) of the specimens varied from 0.5 to 1.0 so that failure modes of chord face failure and chord side wall failure were observed. The test results were compared with the design procedures in the Australian/New Zealand Standard for stainless steel structures, CIDECT and Eurocode design rules for carbon steel structures. It is shown that the design strengths predicted by the current design specifications are conservative for the test specimens calculated using the 0.1%, 0.2%, 0.5% and 1.0% proof stresses as the yield stresses. The 0.2% proof stress is comparatively more reasonable to predict the design strengths of stainless steel welded tubular T-joints for both ultimate limit state and serviceability limit state. In this study, it is shown that the ultimate limit state controls rather than the serviceability limit state for most of the test specimens.
Persistent Identifierhttp://hdl.handle.net/10722/111789
References

 

DC FieldValueLanguage
dc.contributor.authorFeng, Ren_HK
dc.contributor.authorYoung, Ben_HK
dc.date.accessioned2010-09-26T03:04:02Z-
dc.date.available2010-09-26T03:04:02Z-
dc.date.issued2007en_HK
dc.identifier.citation5Th International Conference On Advances In Steel Structures, Icass 2007, 2007, v. 3, p. 563-570en_HK
dc.identifier.urihttp://hdl.handle.net/10722/111789-
dc.description.abstractThis paper describes a test program on a wide range of cold-formed stainless steel welded tubular Tjoints fabricated from square hollow section and rectangular hollow section brace and chord members. A total of 15 tests was performed. High strength stainless steel (duplex and high strength austenitic) specimens were tested. The tests were performed by supporting the chord member of the specimen along its entire length with the pure concentrated force applied to the brace member. The ratio of brace width to chord width (β) of the specimens varied from 0.5 to 1.0 so that failure modes of chord face failure and chord side wall failure were observed. The test results were compared with the design procedures in the Australian/New Zealand Standard for stainless steel structures, CIDECT and Eurocode design rules for carbon steel structures. It is shown that the design strengths predicted by the current design specifications are conservative for the test specimens calculated using the 0.1%, 0.2%, 0.5% and 1.0% proof stresses as the yield stresses. The 0.2% proof stress is comparatively more reasonable to predict the design strengths of stainless steel welded tubular T-joints for both ultimate limit state and serviceability limit state. In this study, it is shown that the ultimate limit state controls rather than the serviceability limit state for most of the test specimens.en_HK
dc.languageengen_HK
dc.relation.ispartof5th International Conference on Advances in Steel Structures, ICASS 2007en_HK
dc.titleTests of T-joints in RHS and SHS high strength stainless steel tubesen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailYoung, B:young@hku.hken_HK
dc.identifier.authorityYoung, B=rp00208en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.scopuseid_2-s2.0-84858040150en_HK
dc.identifier.hkuros149303en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-84858040150&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume3en_HK
dc.identifier.spage563en_HK
dc.identifier.epage570en_HK
dc.identifier.scopusauthoridFeng, R=36138673300en_HK
dc.identifier.scopusauthoridYoung, B=7402192398en_HK

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats