File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/63.974381
- Scopus: eid_2-s2.0-0035520314
- WOS: WOS:000173040400010
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: A comparative study on dimming control methods for electronic ballasts
Title | A comparative study on dimming control methods for electronic ballasts |
---|---|
Authors | |
Keywords | Dimmable electronic ballasts Fluorescent lamps Illumination Illumination control |
Issue Date | 2001 |
Publisher | IEEE |
Citation | Ieee Transactions On Power Electronics, 2001, v. 16 n. 6, p. 828-836 How to Cite? |
Abstract | A comparative study on the performance characteristics between the variable switching frequency scheme (VFS) and variable voltage scheme (VVS) was carried out. By using the fundamental-frequency model and the nonlinear lamp resistance characteristics, the steady state solution and starting voltage characteristics were derived. It was shown that the VVS has several operational advantages over the VFS in dimming operation. |
Persistent Identifier | http://hdl.handle.net/10722/136810 |
ISSN | 2023 Impact Factor: 6.6 2023 SCImago Journal Rankings: 3.644 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ho, YKE | en_HK |
dc.contributor.author | Lee, STS | en_HK |
dc.contributor.author | Chung, HSH | en_HK |
dc.contributor.author | Hui, SY | en_HK |
dc.date.accessioned | 2011-07-29T02:12:48Z | - |
dc.date.available | 2011-07-29T02:12:48Z | - |
dc.date.issued | 2001 | en_HK |
dc.identifier.citation | Ieee Transactions On Power Electronics, 2001, v. 16 n. 6, p. 828-836 | en_HK |
dc.identifier.issn | 0885-8993 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/136810 | - |
dc.description.abstract | A comparative study on the performance characteristics between the variable switching frequency scheme (VFS) and variable voltage scheme (VVS) was carried out. By using the fundamental-frequency model and the nonlinear lamp resistance characteristics, the steady state solution and starting voltage characteristics were derived. It was shown that the VVS has several operational advantages over the VFS in dimming operation. | en_HK |
dc.language | eng | en_US |
dc.publisher | IEEE | en_US |
dc.relation.ispartof | IEEE Transactions on Power Electronics | en_HK |
dc.subject | Dimmable electronic ballasts | en_HK |
dc.subject | Fluorescent lamps | en_HK |
dc.subject | Illumination | en_HK |
dc.subject | Illumination control | en_HK |
dc.title | A comparative study on dimming control methods for electronic ballasts | en_HK |
dc.type | Article | en_HK |
dc.identifier.email | Hui, SY:ronhui@eee.hku.hk | en_HK |
dc.identifier.authority | Hui, SY=rp01510 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1109/63.974381 | en_HK |
dc.identifier.scopus | eid_2-s2.0-0035520314 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0035520314&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 16 | en_HK |
dc.identifier.issue | 6 | en_HK |
dc.identifier.spage | 828 | en_HK |
dc.identifier.epage | 836 | en_HK |
dc.identifier.isi | WOS:000173040400010 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Ho, YKE=22985183700 | en_HK |
dc.identifier.scopusauthorid | Lee, STS=35468613000 | en_HK |
dc.identifier.scopusauthorid | Chung, HSH=7404007467 | en_HK |
dc.identifier.scopusauthorid | Hui, SY=7202831744 | en_HK |
dc.identifier.issnl | 0885-8993 | - |