File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Characterization of coreless printed circuit board (PCB) transformers

TitleCharacterization of coreless printed circuit board (PCB) transformers
Authors
KeywordsInductance
Mathematical Models
Numerical Methods
Optimization
Printed Circuit Boards
Printed Circuit Manufacture
Printed Circuit Testing
Issue Date2000
PublisherIEEE
Citation
Ieee Transactions On Power Electronics, 2000, v. 15 n. 6, p. 1275-1282 How to Cite?
AbstractIn this paper, coreless printed-circuit-board transformers are characterized. A range of coreless printed circuit board (PCB) transformers with different geometric parameters have been fabricated and tested. Based on a recently reported analytic method, the self inductance of these transformers is calculated. This analytical method is also extended to cover the prediction of the transformers' mutual inductance. All calculated parameters have been confirmed with measurements for the frequency range from 100 kHz to 30 MHz. These results provide useful information for the optimal design of coreless PCB transformers.
Persistent Identifierhttp://hdl.handle.net/10722/136829
ISSN
2023 Impact Factor: 6.6
2023 SCImago Journal Rankings: 3.644
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorTang, SCen_HK
dc.contributor.authorHui, SYen_HK
dc.contributor.authorChung, HSHen_HK
dc.date.accessioned2011-07-29T02:12:57Z-
dc.date.available2011-07-29T02:12:57Z-
dc.date.issued2000en_HK
dc.identifier.citationIeee Transactions On Power Electronics, 2000, v. 15 n. 6, p. 1275-1282en_HK
dc.identifier.issn0885-8993en_HK
dc.identifier.urihttp://hdl.handle.net/10722/136829-
dc.description.abstractIn this paper, coreless printed-circuit-board transformers are characterized. A range of coreless printed circuit board (PCB) transformers with different geometric parameters have been fabricated and tested. Based on a recently reported analytic method, the self inductance of these transformers is calculated. This analytical method is also extended to cover the prediction of the transformers' mutual inductance. All calculated parameters have been confirmed with measurements for the frequency range from 100 kHz to 30 MHz. These results provide useful information for the optimal design of coreless PCB transformers.en_HK
dc.languageengen_US
dc.publisherIEEEen_US
dc.relation.ispartofIEEE Transactions on Power Electronicsen_HK
dc.subjectInductanceen_US
dc.subjectMathematical Modelsen_US
dc.subjectNumerical Methodsen_US
dc.subjectOptimizationen_US
dc.subjectPrinted Circuit Boardsen_US
dc.subjectPrinted Circuit Manufactureen_US
dc.subjectPrinted Circuit Testingen_US
dc.titleCharacterization of coreless printed circuit board (PCB) transformersen_HK
dc.typeArticleen_HK
dc.identifier.emailHui, SY:ronhui@eee.hku.hken_HK
dc.identifier.authorityHui, SY=rp01510en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/63.892842en_HK
dc.identifier.scopuseid_2-s2.0-0034313570en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0034313570&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume15en_HK
dc.identifier.issue6en_HK
dc.identifier.spage1275en_HK
dc.identifier.epage1282en_HK
dc.identifier.isiWOS:000166292100033-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridTang, SC=24340444700en_HK
dc.identifier.scopusauthoridHui, SY=7202831744en_HK
dc.identifier.scopusauthoridChung, HSH=7404007467en_HK
dc.identifier.issnl0885-8993-

Export via OAI-PMH Interface in XML Formats


OR