Article: Coreless printed circuit board (PCB) transformers with high power density and high efficiency
Title | Coreless printed circuit board (PCB) transformers with high power density and high efficiency |
---|---|
Authors | |
Issue Date | 2000 |
Publisher | The Institution of Engineering and Technology. The Journal's web site is located at http://www.ieedl.org/EL |
Citation | Electronics Letters, 2000, v. 36 n. 11, p. 943-944 How to Cite? |
Abstract | The authors report the use of a coreless printed circuit board transformer for power conversion with very high power density and efficiency. A coreless PCB transformer with an outermost radius of ∼1 cm and 19 turns for both the primary and secondary windings can transfer 19W at an efficiency of 90%, resulting in a record power density of 24W/cm2. The power density and energy efficiency of a coreless PCB transformer are higher than those of core-based microtransformers. Coreless transformers are simpler in structure, easier to implement in silicon wafer and cheaper than core-based planar transformers. |
Persistent Identifier | http://hdl.handle.net/10722/136837 |
ISSN | 2023 Impact Factor: 0.7 2023 SCImago Journal Rankings: 0.323 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Tang, SC | en_HK |
dc.contributor.author | Hui, SYR | en_HK |
dc.contributor.author | Chung, H | en_HK |
dc.date.accessioned | 2011-07-29T02:13:02Z | - |
dc.date.available | 2011-07-29T02:13:02Z | - |
dc.date.issued | 2000 | en_HK |
dc.identifier.citation | Electronics Letters, 2000, v. 36 n. 11, p. 943-944 | en_HK |
dc.identifier.issn | 0013-5194 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/136837 | - |
dc.description.abstract | The authors report the use of a coreless printed circuit board transformer for power conversion with very high power density and efficiency. A coreless PCB transformer with an outermost radius of ∼1 cm and 19 turns for both the primary and secondary windings can transfer 19W at an efficiency of 90%, resulting in a record power density of 24W/cm2. The power density and energy efficiency of a coreless PCB transformer are higher than those of core-based microtransformers. Coreless transformers are simpler in structure, easier to implement in silicon wafer and cheaper than core-based planar transformers. | en_HK |
dc.language | eng | en_US |
dc.publisher | The Institution of Engineering and Technology. The Journal's web site is located at http://www.ieedl.org/EL | en_HK |
dc.relation.ispartof | Electronics Letters | en_HK |
dc.title | Coreless printed circuit board (PCB) transformers with high power density and high efficiency | en_HK |
dc.type | Article | en_HK |
dc.identifier.email | Hui, SYR:ronhui@eee.hku.hk | en_HK |
dc.identifier.authority | Hui, SYR=rp01510 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.scopus | eid_2-s2.0-0004210114 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0004210114&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 36 | en_HK |
dc.identifier.issue | 11 | en_HK |
dc.identifier.spage | 943 | en_HK |
dc.identifier.epage | 944 | en_HK |
dc.identifier.isi | WOS:000087416200010 | - |
dc.publisher.place | United Kingdom | en_HK |
dc.identifier.scopusauthorid | Tang, SC=24340444700 | en_HK |
dc.identifier.scopusauthorid | Hui, SYR=7202831744 | en_HK |
dc.identifier.scopusauthorid | Chung, H=7404007467 | en_HK |
dc.identifier.issnl | 0013-5194 | - |