Conference Paper: Characterization of coreless Printed Circuit Board (PCB) transformers

TitleCharacterization of coreless Printed Circuit Board (PCB) transformers
Authors
KeywordsApproximation Theory
Electric Frequency Control
Inductance Measurement
Machine Design
Numerical Methods
Optimization
Printed Circuit Boards
Issue Date1999
PublisherIEEE
Citation
Pesc Record - Ieee Annual Power Electronics Specialists Conference, 1999, v. 2, p. 746-752 How to Cite?
AbstractIn this paper, coreless printed-circuit-board transformers are characterized. A range of coreless PCB transformers with different geometric parameters have been fabricated and tested. Based on a recently reported analytic method, the self inductance of these transformers are calculated. This analytical method is also extended to cover the prediction of the transformers' mutual inductance. All calculated parameters have been confirmed with measurements for the frequency range from 100kHz to 30MHz. These results provide useful information for the optimal design of coreless PCB transformers.
Persistent Identifierhttp://hdl.handle.net/10722/136847
ISSN
2019 SCImago Journal Rankings: 0.125

 

DC FieldValueLanguage
dc.contributor.authorTang, SCen_HK
dc.contributor.authorHui, SYRen_HK
dc.contributor.authorChung, Hen_HK
dc.date.accessioned2011-07-29T02:13:06Z-
dc.date.available2011-07-29T02:13:06Z-
dc.date.issued1999en_HK
dc.identifier.citationPesc Record - Ieee Annual Power Electronics Specialists Conference, 1999, v. 2, p. 746-752en_HK
dc.identifier.issn0275-9306en_HK
dc.identifier.urihttp://hdl.handle.net/10722/136847-
dc.description.abstractIn this paper, coreless printed-circuit-board transformers are characterized. A range of coreless PCB transformers with different geometric parameters have been fabricated and tested. Based on a recently reported analytic method, the self inductance of these transformers are calculated. This analytical method is also extended to cover the prediction of the transformers' mutual inductance. All calculated parameters have been confirmed with measurements for the frequency range from 100kHz to 30MHz. These results provide useful information for the optimal design of coreless PCB transformers.en_HK
dc.languageengen_US
dc.publisherIEEEen_US
dc.relation.ispartofPESC Record - IEEE Annual Power Electronics Specialists Conferenceen_HK
dc.subjectApproximation Theoryen_US
dc.subjectElectric Frequency Controlen_US
dc.subjectInductance Measurementen_US
dc.subjectMachine Designen_US
dc.subjectNumerical Methodsen_US
dc.subjectOptimizationen_US
dc.subjectPrinted Circuit Boardsen_US
dc.titleCharacterization of coreless Printed Circuit Board (PCB) transformersen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailHui, SYR:ronhui@eee.hku.hken_HK
dc.identifier.authorityHui, SYR=rp01510en_HK
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1109/PESC.1999.785593en_HK
dc.identifier.scopuseid_2-s2.0-0033325555en_HK
dc.identifier.volume2en_HK
dc.identifier.spage746en_HK
dc.identifier.epage752en_HK
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridTang, SC=24340444700en_HK
dc.identifier.scopusauthoridHui, SYR=7202831744en_HK
dc.identifier.scopusauthoridChung, H=7404007467en_HK
dc.identifier.issnl0275-9306-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats