File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/TIE.2007.899926
- Scopus: eid_2-s2.0-44449105395
- WOS: WOS:000249841600021
- Find via
Supplementary
-
Bookmarks:
- CiteULike: 1
- Citations:
- Appears in Collections:
Article: State-of-charge determination from EMF voltage estimation: Using impedance, terminal voltage, and current for lead-acid and lithium-ion batteries
Title | State-of-charge determination from EMF voltage estimation: Using impedance, terminal voltage, and current for lead-acid and lithium-ion batteries |
---|---|
Authors | |
Keywords | C rate Electromotive force (EMF) voltage Impedance Lead-acid battery Lithium-ion battery State of charge (SOC) Terminal voltage |
Issue Date | 2007 |
Publisher | I E E E. The Journal's web site is located at http://www.ewh.ieee.org/soc/ies/ties/index.html |
Citation | Ieee Transactions On Industrial Electronics, 2007, v. 54 n. 5, p. 2550-2557 How to Cite? |
Abstract | State-of-charge (SOC) determination is an increasingly important issue in battery technology. In addition to the immediate display of the remaining battery capacity to the user, precise knowledge of SOC exerts additional control over the charging/discharging process, which can be employed to increase battery life. This reduces the risk of overvoltage and gassing, which degrade the chemical composition of the electrolyte and plates. The proposed model in this paper determines the SOC by incorporating the changes occurring due to terminal voltage, current load, and internal resistance, which mitigate the disadvantages of using impedance only. Electromotive force (EMF) voltage is predicted while the battery is under load conditions; from the estimated EMF voltage, the SOC is then determined. The method divides the battery voltage curve into two regions: 1) the linear region for full to partial SOC and 2) the hyperbolic region from partial to low SOC. Algorithms are developed to correspond to the different characteristic changes occurring within each region. In the hyperbolic region, the rate of change in impedance and terminal voltage is greater than that in the linear region. The magnitude of current discharge causes varying rates of change to the terminal voltage and impedance. Experimental tests and results are presented to validate the new models. © 2007 IEEE. |
Persistent Identifier | http://hdl.handle.net/10722/145456 |
ISSN | 2023 Impact Factor: 7.5 2023 SCImago Journal Rankings: 3.395 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Coleman, M | en_HK |
dc.contributor.author | Lee, CK | en_HK |
dc.contributor.author | Zhu, C | en_HK |
dc.contributor.author | Hurley, WG | en_HK |
dc.date.accessioned | 2012-02-23T12:10:36Z | - |
dc.date.available | 2012-02-23T12:10:36Z | - |
dc.date.issued | 2007 | en_HK |
dc.identifier.citation | Ieee Transactions On Industrial Electronics, 2007, v. 54 n. 5, p. 2550-2557 | en_HK |
dc.identifier.issn | 0278-0046 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/145456 | - |
dc.description.abstract | State-of-charge (SOC) determination is an increasingly important issue in battery technology. In addition to the immediate display of the remaining battery capacity to the user, precise knowledge of SOC exerts additional control over the charging/discharging process, which can be employed to increase battery life. This reduces the risk of overvoltage and gassing, which degrade the chemical composition of the electrolyte and plates. The proposed model in this paper determines the SOC by incorporating the changes occurring due to terminal voltage, current load, and internal resistance, which mitigate the disadvantages of using impedance only. Electromotive force (EMF) voltage is predicted while the battery is under load conditions; from the estimated EMF voltage, the SOC is then determined. The method divides the battery voltage curve into two regions: 1) the linear region for full to partial SOC and 2) the hyperbolic region from partial to low SOC. Algorithms are developed to correspond to the different characteristic changes occurring within each region. In the hyperbolic region, the rate of change in impedance and terminal voltage is greater than that in the linear region. The magnitude of current discharge causes varying rates of change to the terminal voltage and impedance. Experimental tests and results are presented to validate the new models. © 2007 IEEE. | en_HK |
dc.language | eng | en_US |
dc.publisher | I E E E. The Journal's web site is located at http://www.ewh.ieee.org/soc/ies/ties/index.html | en_HK |
dc.relation.ispartof | IEEE Transactions on Industrial Electronics | en_HK |
dc.subject | C rate | en_HK |
dc.subject | Electromotive force (EMF) voltage | en_HK |
dc.subject | Impedance | en_HK |
dc.subject | Lead-acid battery | en_HK |
dc.subject | Lithium-ion battery | en_HK |
dc.subject | State of charge (SOC) | en_HK |
dc.subject | Terminal voltage | en_HK |
dc.title | State-of-charge determination from EMF voltage estimation: Using impedance, terminal voltage, and current for lead-acid and lithium-ion batteries | en_HK |
dc.type | Article | en_HK |
dc.identifier.email | Lee, CK:cklee@eee.hku.hk | en_HK |
dc.identifier.authority | Lee, CK=rp01580 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1109/TIE.2007.899926 | en_HK |
dc.identifier.scopus | eid_2-s2.0-44449105395 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-44449105395&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 54 | en_HK |
dc.identifier.issue | 5 | en_HK |
dc.identifier.spage | 2550 | en_HK |
dc.identifier.epage | 2557 | en_HK |
dc.identifier.isi | WOS:000249841600021 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Coleman, M=24334321500 | en_HK |
dc.identifier.scopusauthorid | Lee, CK=24537405500 | en_HK |
dc.identifier.scopusauthorid | Zhu, C=7403440134 | en_HK |
dc.identifier.scopusauthorid | Hurley, WG=7102840628 | en_HK |
dc.identifier.citeulike | 7748480 | - |
dc.identifier.issnl | 0278-0046 | - |