File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: 207pb/ 206pb determination of zircons by laser probe-inductively coupled plasma mass spectrometry

Title207pb/ 206pb determination of zircons by laser probe-inductively coupled plasma mass spectrometry
Authors
KeywordsLaser Probe-Inductively Coupled Plasma Mass Spectrometry
Microanalysis
Zircon
Issue Date1998
PublisherScience China Press. The Journal's web site is located at http://www.springerlink.com/content/1001-6538/
Citation
Chinese Science Bulletin, 1998, v. 43 n. 23, p. 2008-2012 How to Cite?
AbstractLaser probe-inductively coupled plasma mass spectrometry (LP-ICP-MS) was used to determine 207Pb/ 206Pb ratios in single zircon grains. A Nd: YAG laser operating at 1 064 nm and a Fisons-VG PQII Turbo ICP-MS were employed. For the known zircons, the 207Pb/ 206Pb results of LP-ICP-MS are close to the thermal ionization mass spectrometry (TIMS) results. The spatial resolution of this method is 40-50 μm and the sensitivities for lead isotopes are about 300-400 cps/ppm. The precision of 207Pb/ 206Pb ratio is 0.3%-4% and depends on the lead concentration of the sampling pits. LP-ICPMS provides a simple, rapid and economic method for zircon 207Pb/ 206Pb determination.
Persistent Identifierhttp://hdl.handle.net/10722/151124
ISSN
2016 Impact Factor: 1.649
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorVan, Xen_US
dc.contributor.authorChu, Zen_US
dc.contributor.authorSun, Men_US
dc.contributor.authorXu, Pen_US
dc.contributor.authorZhou, Xen_US
dc.date.accessioned2012-06-26T06:17:24Z-
dc.date.available2012-06-26T06:17:24Z-
dc.date.issued1998en_US
dc.identifier.citationChinese Science Bulletin, 1998, v. 43 n. 23, p. 2008-2012en_US
dc.identifier.issn1001-6538en_US
dc.identifier.urihttp://hdl.handle.net/10722/151124-
dc.description.abstractLaser probe-inductively coupled plasma mass spectrometry (LP-ICP-MS) was used to determine 207Pb/ 206Pb ratios in single zircon grains. A Nd: YAG laser operating at 1 064 nm and a Fisons-VG PQII Turbo ICP-MS were employed. For the known zircons, the 207Pb/ 206Pb results of LP-ICP-MS are close to the thermal ionization mass spectrometry (TIMS) results. The spatial resolution of this method is 40-50 μm and the sensitivities for lead isotopes are about 300-400 cps/ppm. The precision of 207Pb/ 206Pb ratio is 0.3%-4% and depends on the lead concentration of the sampling pits. LP-ICPMS provides a simple, rapid and economic method for zircon 207Pb/ 206Pb determination.en_US
dc.languageengen_US
dc.publisherScience China Press. The Journal's web site is located at http://www.springerlink.com/content/1001-6538/en_US
dc.relation.ispartofChinese Science Bulletinen_US
dc.subjectLaser Probe-Inductively Coupled Plasma Mass Spectrometryen_US
dc.subjectMicroanalysisen_US
dc.subjectZirconen_US
dc.title207pb/ 206pb determination of zircons by laser probe-inductively coupled plasma mass spectrometryen_US
dc.typeArticleen_US
dc.identifier.emailSun, M:minsun@hku.hken_US
dc.identifier.authoritySun, M=rp00780en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.doi10.1007/BF03186995-
dc.identifier.scopuseid_2-s2.0-0542378625en_US
dc.identifier.hkuros47079-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0542378625&selection=ref&src=s&origin=recordpageen_US
dc.identifier.volume43en_US
dc.identifier.issue23en_US
dc.identifier.spage2008en_US
dc.identifier.epage2012en_US
dc.identifier.isiWOS:000078003700015-
dc.publisher.placeChinaen_US
dc.identifier.scopusauthoridVan, X=6506699126en_US
dc.identifier.scopusauthoridChu, Z=7101763057en_US
dc.identifier.scopusauthoridSun, M=25932315800en_US
dc.identifier.scopusauthoridXu, P=49161291100en_US
dc.identifier.scopusauthoridZhou, X=7410089813en_US
dc.identifier.issnl1001-6538-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats