File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/59.373945
- Scopus: eid_2-s2.0-0029252793
- WOS: WOS:A1995QK23600026
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Voltage dependent reactive power limits for voltage stability studies
Title | Voltage dependent reactive power limits for voltage stability studies |
---|---|
Authors | |
Issue Date | 1995 |
Publisher | I E E E. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=59 |
Citation | Ieee Transactions On Power Systems, 1995, v. 10 n. 1, p. 220-228 How to Cite? |
Abstract | This paper presents and studies a static model for synchronous generators with voltage dependent reactive power limits due to maximum stator current, maximum and minimum rotor (field) current as well as maximum rotor angle (underexcitation) limiters. The proposed generator model for static voltage stability studies can be included in an ordinary power flow program, and results from studies on a test system with twenty generators are presented. The influence of voltage dependent reactive power limits is compared with fixed (conventional) limits, by use of the minimum singular value of the power flow Jacobian matrix and related submatrices as indicators of the static voltage stability limit. |
Persistent Identifier | http://hdl.handle.net/10722/169642 |
ISSN | 2023 Impact Factor: 6.5 2023 SCImago Journal Rankings: 3.827 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lof, PA | en_US |
dc.contributor.author | Andersson, G | en_US |
dc.contributor.author | Hill, DJ | en_US |
dc.date.accessioned | 2012-10-25T04:53:59Z | - |
dc.date.available | 2012-10-25T04:53:59Z | - |
dc.date.issued | 1995 | en_US |
dc.identifier.citation | Ieee Transactions On Power Systems, 1995, v. 10 n. 1, p. 220-228 | en_US |
dc.identifier.issn | 0885-8950 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/169642 | - |
dc.description.abstract | This paper presents and studies a static model for synchronous generators with voltage dependent reactive power limits due to maximum stator current, maximum and minimum rotor (field) current as well as maximum rotor angle (underexcitation) limiters. The proposed generator model for static voltage stability studies can be included in an ordinary power flow program, and results from studies on a test system with twenty generators are presented. The influence of voltage dependent reactive power limits is compared with fixed (conventional) limits, by use of the minimum singular value of the power flow Jacobian matrix and related submatrices as indicators of the static voltage stability limit. | en_US |
dc.language | eng | en_US |
dc.publisher | I E E E. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=59 | en_US |
dc.relation.ispartof | IEEE Transactions on Power Systems | en_US |
dc.title | Voltage dependent reactive power limits for voltage stability studies | en_US |
dc.type | Article | en_US |
dc.identifier.email | Hill, DJ: | en_US |
dc.identifier.authority | Hill, DJ=rp01669 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1109/59.373945 | en_US |
dc.identifier.scopus | eid_2-s2.0-0029252793 | en_US |
dc.identifier.volume | 10 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.spage | 220 | en_US |
dc.identifier.epage | 228 | en_US |
dc.identifier.isi | WOS:A1995QK23600026 | - |
dc.publisher.place | United States | en_US |
dc.identifier.scopusauthorid | Lof, PA=6506932700 | en_US |
dc.identifier.scopusauthorid | Andersson, G=35552392600 | en_US |
dc.identifier.scopusauthorid | Hill, DJ=35398599500 | en_US |
dc.identifier.issnl | 0885-8950 | - |