Conference Paper: Coordinated steady-state voltage stability assessment and control

TitleCoordinated steady-state voltage stability assessment and control
Authors
Issue Date1998
Citation
Iee Conference Publication, 1998 n. 450, p. 248-253 How to Cite?
AbstractA framework for mid and long term small disturbance voltage stability assessment and control with dissimilar controls is presented. The parameter space includes parameters for loads, capacitor support and tap changing transformers. A general method is used to locate all the small disturbance characteristic points which contains saddle-node bifurcation, Hopf bifurcation and minimum damping points. The distances from the operating point to the global and/or local closest points in stability boundaries are used as security indices. A new function, defined in terms of multiple (local) minimum distances and the safe distance needed, is used to evaluate the security margin and find the most effective control actions to increase the security margin. All these methods are tested and illustrated in a given example system.
Persistent Identifierhttp://hdl.handle.net/10722/169795
ISSN
2019 SCImago Journal Rankings: 0.101

 

DC FieldValueLanguage
dc.contributor.authorMakarov, Yuri Ven_US
dc.contributor.authorWu, Qiangen_US
dc.contributor.authorHill, David Jen_US
dc.contributor.authorPopovic, Dragana Hen_US
dc.contributor.authorDong, Zhao Yangen_US
dc.date.accessioned2012-10-25T04:55:38Z-
dc.date.available2012-10-25T04:55:38Z-
dc.date.issued1998en_US
dc.identifier.citationIee Conference Publication, 1998 n. 450, p. 248-253en_US
dc.identifier.issn0537-9989en_US
dc.identifier.urihttp://hdl.handle.net/10722/169795-
dc.description.abstractA framework for mid and long term small disturbance voltage stability assessment and control with dissimilar controls is presented. The parameter space includes parameters for loads, capacitor support and tap changing transformers. A general method is used to locate all the small disturbance characteristic points which contains saddle-node bifurcation, Hopf bifurcation and minimum damping points. The distances from the operating point to the global and/or local closest points in stability boundaries are used as security indices. A new function, defined in terms of multiple (local) minimum distances and the safe distance needed, is used to evaluate the security margin and find the most effective control actions to increase the security margin. All these methods are tested and illustrated in a given example system.en_US
dc.languageengen_US
dc.relation.ispartofIEE Conference Publicationen_US
dc.titleCoordinated steady-state voltage stability assessment and controlen_US
dc.typeConference_Paperen_US
dc.identifier.emailHill, David J:en_US
dc.identifier.authorityHill, David J=rp01669en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.scopuseid_2-s2.0-0031599117en_US
dc.identifier.issue450en_US
dc.identifier.spage248en_US
dc.identifier.epage253en_US
dc.identifier.scopusauthoridMakarov, Yuri V=35461311800en_US
dc.identifier.scopusauthoridWu, Qiang=35468560800en_US
dc.identifier.scopusauthoridHill, David J=35398599500en_US
dc.identifier.scopusauthoridPopovic, Dragana H=22956344500en_US
dc.identifier.scopusauthoridDong, Zhao Yang=7402274708en_US
dc.identifier.issnl0537-9989-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats