Conference Paper: System security enhancement against voltage collapse via coordinated control

TitleSystem security enhancement against voltage collapse via coordinated control
Authors
Issue Date1999
Citation
Ieee Engineering Society, Winter Meeting, 1999, v. 1, p. 755-760 How to Cite?
AbstractIn this paper, the problem of analytically coordinating dissimilar voltage control actions to prevent voltage collapse in a large power system is addressed. A framework for hybrid control based on coordination of controls with different response time and dynamic characteristics is presented. The proposed method is based on a security constrained steady-state approach. The minimum distance from the operating point to the bifurcation boundary is used to evaluate system security. The optimal corrective control direction towards adequate security is then obtained by calculating the sensitivity of the minimum distance with respect to controls. The actual dispatch of controls along the optimal direction, which takes into account impacts of economic cost and control availability, is determined as the solution of a multiple stage optimization problem using differential dynamic programming. The algorithm is demonstrated for a system with dynamic load models representing the main grid of the New South Wales, Australia.
Persistent Identifierhttp://hdl.handle.net/10722/169797

 

DC FieldValueLanguage
dc.contributor.authorWu, Qiangen_US
dc.contributor.authorPopovic, Dragana Hen_US
dc.contributor.authorHill, David Jen_US
dc.contributor.authorParker, Colin Jen_US
dc.date.accessioned2012-10-25T04:55:39Z-
dc.date.available2012-10-25T04:55:39Z-
dc.date.issued1999en_US
dc.identifier.citationIeee Engineering Society, Winter Meeting, 1999, v. 1, p. 755-760en_US
dc.identifier.urihttp://hdl.handle.net/10722/169797-
dc.description.abstractIn this paper, the problem of analytically coordinating dissimilar voltage control actions to prevent voltage collapse in a large power system is addressed. A framework for hybrid control based on coordination of controls with different response time and dynamic characteristics is presented. The proposed method is based on a security constrained steady-state approach. The minimum distance from the operating point to the bifurcation boundary is used to evaluate system security. The optimal corrective control direction towards adequate security is then obtained by calculating the sensitivity of the minimum distance with respect to controls. The actual dispatch of controls along the optimal direction, which takes into account impacts of economic cost and control availability, is determined as the solution of a multiple stage optimization problem using differential dynamic programming. The algorithm is demonstrated for a system with dynamic load models representing the main grid of the New South Wales, Australia.en_US
dc.languageengen_US
dc.relation.ispartofIEEE Engineering Society, Winter Meetingen_US
dc.titleSystem security enhancement against voltage collapse via coordinated controlen_US
dc.typeConference_Paperen_US
dc.identifier.emailHill, David J:en_US
dc.identifier.authorityHill, David J=rp01669en_US
dc.description.naturelink_to_subscribed_fulltexten_US
dc.identifier.scopuseid_2-s2.0-0032652365en_US
dc.identifier.volume1en_US
dc.identifier.spage755en_US
dc.identifier.epage760en_US
dc.identifier.scopusauthoridWu, Qiang=35468560800en_US
dc.identifier.scopusauthoridPopovic, Dragana H=22956344500en_US
dc.identifier.scopusauthoridHill, David J=35398599500en_US
dc.identifier.scopusauthoridParker, Colin J=7402174388en_US

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats