File Download

There are no files associated with this item.

Supplementary

Conference Paper: Multi-band PROPELLER imaging with auto-calibration

TitleMulti-band PROPELLER imaging with auto-calibration
Authors
Issue Date2015
Citation
The 23rd Annual Meeting & Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM) and SMRT 24th Annual Meeting, Toronto, ON., Canada, 30 May-5 June 2015, poster no. 2411 How to Cite?
AbstractPROPELLER MRI is widely used nowadays for motion correction. One major drawback of PROPELLER MRI is the long scan time. Previous studies have investigated in-plane acceleration (SENSE and GRAPPA) in PROPELLER1,5. However, multi-band (MB) simultaneous multi-slice acquisition, without SNR penalty proportional to square root of acceleration ratio, can be a more suitable solution for accelerating PROPELLER. In addition, MB acquisition combining PINS RF pulses2 can reduce RF pulse power deposition, which is particularly useful for alleviating the SAR issue in FSE-PROPELLER at high field. A considerably low g-factor is possible in MB PROPELLER because its rotating phase encoding directions can consequently lead to a well-conditioned unwrapping problem. Another advantage of MB PROPELLER is that 3D coil sensitivity maps (CSMs) can be directly estimated from the oversampled k-space center, without acquiring additional calibration data.
DescriptionTraditional Poster Session: Pulse Sequences & Reconstruction - Multi-Band MRI: no. 2411
Persistent Identifierhttp://hdl.handle.net/10722/220310

 

DC FieldValueLanguage
dc.contributor.authorLyu, MY-
dc.contributor.authorLiu, YL-
dc.contributor.authorXie, VB-
dc.contributor.authorDai, EP-
dc.contributor.authorGuo, H-
dc.contributor.authorWu, EX-
dc.date.accessioned2015-10-16T06:37:15Z-
dc.date.available2015-10-16T06:37:15Z-
dc.date.issued2015-
dc.identifier.citationThe 23rd Annual Meeting & Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM) and SMRT 24th Annual Meeting, Toronto, ON., Canada, 30 May-5 June 2015, poster no. 2411-
dc.identifier.urihttp://hdl.handle.net/10722/220310-
dc.descriptionTraditional Poster Session: Pulse Sequences & Reconstruction - Multi-Band MRI: no. 2411-
dc.description.abstractPROPELLER MRI is widely used nowadays for motion correction. One major drawback of PROPELLER MRI is the long scan time. Previous studies have investigated in-plane acceleration (SENSE and GRAPPA) in PROPELLER1,5. However, multi-band (MB) simultaneous multi-slice acquisition, without SNR penalty proportional to square root of acceleration ratio, can be a more suitable solution for accelerating PROPELLER. In addition, MB acquisition combining PINS RF pulses2 can reduce RF pulse power deposition, which is particularly useful for alleviating the SAR issue in FSE-PROPELLER at high field. A considerably low g-factor is possible in MB PROPELLER because its rotating phase encoding directions can consequently lead to a well-conditioned unwrapping problem. Another advantage of MB PROPELLER is that 3D coil sensitivity maps (CSMs) can be directly estimated from the oversampled k-space center, without acquiring additional calibration data.-
dc.languageeng-
dc.relation.ispartofISMRM 23rd Annual Meeting & Exhibition cum SMRT 24th Annual Meeting Proceedings-
dc.titleMulti-band PROPELLER imaging with auto-calibration-
dc.typeConference_Paper-
dc.identifier.emailWu, EX: ewu@eee.hku.hk-
dc.identifier.authorityWu, EX=rp00193-
dc.identifier.hkuros255291-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats