Article: B-spline interpolation for bend intra-oral radiographs
Title | B-spline interpolation for bend intra-oral radiographs |
---|---|
Authors | |
Keywords | B-spline interpolation Bend error Digital subtraction radiography Image scaling Warping |
Issue Date | 2007 |
Publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/compbiomed |
Citation | Computers in Biology and Medicine, 2007, v. 37 n. 11, p. 1565-1571 How to Cite? |
Abstract | Digital subtraction radiography (DSR) has been demonstrated to improve the detection of minute bone changes during the diagnosis of Periodontal diseases. However, during a dental X-ray session, it is not possible to control the bending of the X-ray film when installed in a patient's mouth. This leads to errors in the subsequent analysis. Error compensation can be done by a warping transformation, in conjunction with a reference wire grid attached to the X-ray film. However, the wire grid has to be attached to the film manually. The grid itself is a source of error in that it obscures the image and causes information loss. In this paper we propose a compensation method without the use of a reference grid. It is a simple algorithm based on B-spline interpolation and image scaling. No prior information about the bending is required. When compared with warping transformation, the method induces less disturbance to the pixel values during the compensation process. As a result, the proposed method produces more accurate image data for subsequent analysis. |
Persistent Identifier | http://hdl.handle.net/10722/222789 |
ISSN | 2023 Impact Factor: 7.0 2023 SCImago Journal Rankings: 1.481 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Leung, CC | - |
dc.contributor.author | Kwok, PC | - |
dc.contributor.author | Zee, KY | - |
dc.contributor.author | Chan, FHY | - |
dc.date.accessioned | 2016-01-29T03:06:15Z | - |
dc.date.available | 2016-01-29T03:06:15Z | - |
dc.date.issued | 2007 | - |
dc.identifier.citation | Computers in Biology and Medicine, 2007, v. 37 n. 11, p. 1565-1571 | - |
dc.identifier.issn | 0010-4825 | - |
dc.identifier.uri | http://hdl.handle.net/10722/222789 | - |
dc.description.abstract | Digital subtraction radiography (DSR) has been demonstrated to improve the detection of minute bone changes during the diagnosis of Periodontal diseases. However, during a dental X-ray session, it is not possible to control the bending of the X-ray film when installed in a patient's mouth. This leads to errors in the subsequent analysis. Error compensation can be done by a warping transformation, in conjunction with a reference wire grid attached to the X-ray film. However, the wire grid has to be attached to the film manually. The grid itself is a source of error in that it obscures the image and causes information loss. In this paper we propose a compensation method without the use of a reference grid. It is a simple algorithm based on B-spline interpolation and image scaling. No prior information about the bending is required. When compared with warping transformation, the method induces less disturbance to the pixel values during the compensation process. As a result, the proposed method produces more accurate image data for subsequent analysis. | - |
dc.language | eng | - |
dc.publisher | Pergamon. The Journal's web site is located at http://www.elsevier.com/locate/compbiomed | - |
dc.relation.ispartof | Computers in Biology and Medicine | - |
dc.rights | © <year>. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | B-spline interpolation | - |
dc.subject | Bend error | - |
dc.subject | Digital subtraction radiography | - |
dc.subject | Image scaling | - |
dc.subject | Warping | - |
dc.subject.mesh | Algorithms | - |
dc.subject.mesh | Humans | - |
dc.subject.mesh | Periodontal Diseases - radiography | - |
dc.subject.mesh | Radiography, Dental, Digital - statistics & numerical data | - |
dc.subject.mesh | Subtraction Technique - statistics & numerical data | - |
dc.title | B-spline interpolation for bend intra-oral radiographs | - |
dc.type | Article | - |
dc.identifier.email | Leung, CC: ccleung@eee.hku.hk | - |
dc.identifier.email | Zee, KY: kyzee@hkusub.hku.hk | - |
dc.identifier.email | Chan, FHY: fhychan@eee.hku.hk | - |
dc.identifier.doi | 10.1016/j.compbiomed.2007.02.004 | - |
dc.identifier.pmid | 17416358 | - |
dc.identifier.scopus | eid_2-s2.0-34548451660 | - |
dc.identifier.volume | 37 | - |
dc.identifier.issue | 11 | - |
dc.identifier.spage | 1565 | - |
dc.identifier.epage | 1571 | - |
dc.identifier.isi | WOS:000250185300004 | - |
dc.publisher.place | United Kingdom | - |
dc.identifier.issnl | 0010-4825 | - |