TitleEffects of axial load on seismic performance of reinforced concrete walls with short shear span
Authors
KeywordsAxial load collapse
Reinforced concrete
Seismic behaviour
Shear walls
Short shear span
Issue Date2017
PublisherPergamon. The Journal's web site is located at http://www.elsevier.com/locate/engstruct
Citation
Engineering Structures, 2017, v. 151, p. 312-326 How to Cite?
AbstractReinforced concrete (RC) shear walls in tall buildings are found to have a short shear span, particularly in high-degree coupled walls supported on transfer structures in low-to-moderate seismic regions. These non-seismically detailed walls in existing buildings are exposed to a high risk of failing in shear or compression before plastic hinges are formed at their base. Whilst previous research have focused on squat walls used in low-rise structures tested with zero or low axial loads, the structural response of these walls with a short shear span and limited ductility under high axial load is rarely discussed. Therefore, an experimental study that investigates the influence of the axial load ratio.(ALR) on RC walls with a short shear span is presented in this paper. The specimens are designed with a low shear span-to-length ratio (SLR) and detailed with a characteristic 2% vertical and longitudinal reinforcement to represent a wall sub-structure above the transfer structure of tall buildings. Four walls are tested under reverse cyclic loading and subjected to target ALRs that range from 0.1 to 0.4 to investigate the seismic performance until gravity collapse. The ALR is found to have significant effects on crack patterns, failure modes and deformability. Two modified empirical prediction models are proposed to estimate the shear strength capacity and ultimate drift ratio of rectangular RC shear walls with a short shear span under the effects of the ALR A unique model of the drift limit of collapse under axial load as a function of the reinforcement ratio is put forward for performance based design and assessment.
Persistent Identifierhttp://hdl.handle.net/10722/254931
ISSN
2021 Impact Factor: 5.582
2020 SCImago Journal Rankings: 1.567
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLOOI, TW-
dc.contributor.authorSu, KL-
dc.contributor.authorCheng, B-
dc.contributor.authorTsang, HH-
dc.date.accessioned2018-06-21T01:08:48Z-
dc.date.available2018-06-21T01:08:48Z-
dc.date.issued2017-
dc.identifier.citationEngineering Structures, 2017, v. 151, p. 312-326-
dc.identifier.issn0141-0296-
dc.identifier.urihttp://hdl.handle.net/10722/254931-
dc.description.abstractReinforced concrete (RC) shear walls in tall buildings are found to have a short shear span, particularly in high-degree coupled walls supported on transfer structures in low-to-moderate seismic regions. These non-seismically detailed walls in existing buildings are exposed to a high risk of failing in shear or compression before plastic hinges are formed at their base. Whilst previous research have focused on squat walls used in low-rise structures tested with zero or low axial loads, the structural response of these walls with a short shear span and limited ductility under high axial load is rarely discussed. Therefore, an experimental study that investigates the influence of the axial load ratio.(ALR) on RC walls with a short shear span is presented in this paper. The specimens are designed with a low shear span-to-length ratio (SLR) and detailed with a characteristic 2% vertical and longitudinal reinforcement to represent a wall sub-structure above the transfer structure of tall buildings. Four walls are tested under reverse cyclic loading and subjected to target ALRs that range from 0.1 to 0.4 to investigate the seismic performance until gravity collapse. The ALR is found to have significant effects on crack patterns, failure modes and deformability. Two modified empirical prediction models are proposed to estimate the shear strength capacity and ultimate drift ratio of rectangular RC shear walls with a short shear span under the effects of the ALR A unique model of the drift limit of collapse under axial load as a function of the reinforcement ratio is put forward for performance based design and assessment.-
dc.languageeng-
dc.publisherPergamon. The Journal's web site is located at http://www.elsevier.com/locate/engstruct-
dc.relation.ispartofEngineering Structures-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectAxial load collapse-
dc.subjectReinforced concrete-
dc.subjectSeismic behaviour-
dc.subjectShear walls-
dc.subjectShort shear span-
dc.titleEffects of axial load on seismic performance of reinforced concrete walls with short shear span-
dc.typeArticle-
dc.identifier.emailSu, KL: klsu@hkucc.hku.hk-
dc.identifier.authoritySu, KL=rp00072-
dc.description.naturepostprint-
dc.identifier.doi10.1016/j.engstruct.2017.08.030-
dc.identifier.scopuseid_2-s2.0-85028053029-
dc.identifier.hkuros285561-
dc.identifier.volume151-
dc.identifier.spage312-
dc.identifier.epage326-
dc.identifier.isiWOS:000412960600024-
dc.publisher.placeUnited Kingdom-
dc.identifier.issnl0141-0296-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats