Conference Paper: Structural Performance of Concrete-filled Double Skin Tubular Beams with Eccentric Inner Tubes

TitleStructural Performance of Concrete-filled Double Skin Tubular Beams with Eccentric Inner Tubes
Authors
Issue Date2017
PublisherCRC Press.
Citation
Tubular Structures XVI: Proceedings of the 16th International Symposium on Tubular Structures (ISTS), Melbourne, Australia, 4-6 December 2017, p. 117-123 How to Cite?
AbstractConcrete-Filled Double Skin Tubular (CFDST) beams with stainless steel as the outer tube, carbon steel as the inner tube and sandwiched concrete infill between the tubes are presented. Previous studies on CFDST beams have revealed significant enhancements in flexural capacity due to the interaction between concrete and metal tubes. In this study, an innovative form of CFDST beam has been proposed, whereby the inner tube is positioned in the tensile zone of the sections. Hence, the beam sections can resist higher bending moment compared to those sections with the inner tube located at the centroid. A series of tests was performed on CFDST beams with an eccentric inner tube. Nine three-point major-axis bending tests were conducted. The full moment–deflection histories, moment capacities and failure modes of the CFDST beams are presented herein. The experimental results were used to evaluate the bending resistances predicted by the American and European Specifications.
Persistent Identifierhttp://hdl.handle.net/10722/259849
ISBN

 

DC FieldValueLanguage
dc.contributor.authorWang, F-
dc.contributor.authorYoung, B-
dc.contributor.authorGardner, L-
dc.date.accessioned2018-09-03T04:15:01Z-
dc.date.available2018-09-03T04:15:01Z-
dc.date.issued2017-
dc.identifier.citationTubular Structures XVI: Proceedings of the 16th International Symposium on Tubular Structures (ISTS), Melbourne, Australia, 4-6 December 2017, p. 117-123-
dc.identifier.isbn978-0815381341-
dc.identifier.urihttp://hdl.handle.net/10722/259849-
dc.description.abstractConcrete-Filled Double Skin Tubular (CFDST) beams with stainless steel as the outer tube, carbon steel as the inner tube and sandwiched concrete infill between the tubes are presented. Previous studies on CFDST beams have revealed significant enhancements in flexural capacity due to the interaction between concrete and metal tubes. In this study, an innovative form of CFDST beam has been proposed, whereby the inner tube is positioned in the tensile zone of the sections. Hence, the beam sections can resist higher bending moment compared to those sections with the inner tube located at the centroid. A series of tests was performed on CFDST beams with an eccentric inner tube. Nine three-point major-axis bending tests were conducted. The full moment–deflection histories, moment capacities and failure modes of the CFDST beams are presented herein. The experimental results were used to evaluate the bending resistances predicted by the American and European Specifications.-
dc.languageeng-
dc.publisherCRC Press.-
dc.relation.ispartofTubular Structures XVI: Proceedings of the 16th International Symposium on Tubular Structures, 2017-
dc.titleStructural Performance of Concrete-filled Double Skin Tubular Beams with Eccentric Inner Tubes-