Article: Restoration of Power Distribution Systems With Multiple Data Centers as Critical Loads
Title | Restoration of Power Distribution Systems With Multiple Data Centers as Critical Loads |
---|---|
Authors | |
Keywords | Power distribution Power supplies Computational modeling Critical infrastructure Optimization |
Issue Date | 2019 |
Citation | IEEE Transactions on Smart Grid, 2019, v. 10 n. 5, p. 5294-5307 How to Cite? |
Abstract | In this paper, a post-event restoration method is proposed for power distribution systems with Internet data centers (IDCs) as critical loads. The proposed method is formulated as a mixed integer linear programming-based optimization model which considers emergency operation decisions in IDCs and restoration decisions in power distribution systems, and can minimize the utility loss of IDCs and other loads during the restoration process. Since the original form of the proposed method may face some problems in practical application, such as confidential information sharing and long computing time, a decoupling method is proposed to convert the integrated model into several sequential parts which are operated by power distribution systems or IDCs independently, so that the confidential information sharing issue is solved, and the computing time is significantly reduced. The proposed restoration method is tested on the IEEE 123-Bus Feeder with multiple IDCs to illustrate its feasibility and efficiency. |
Persistent Identifier | http://hdl.handle.net/10722/277977 |
ISSN | 2023 Impact Factor: 8.6 2023 SCImago Journal Rankings: 4.863 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | LIU, Y | - |
dc.contributor.author | Lei, S | - |
dc.contributor.author | Hou, Y | - |
dc.date.accessioned | 2019-10-04T08:05:02Z | - |
dc.date.available | 2019-10-04T08:05:02Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | IEEE Transactions on Smart Grid, 2019, v. 10 n. 5, p. 5294-5307 | - |
dc.identifier.issn | 1949-3053 | - |
dc.identifier.uri | http://hdl.handle.net/10722/277977 | - |
dc.description.abstract | In this paper, a post-event restoration method is proposed for power distribution systems with Internet data centers (IDCs) as critical loads. The proposed method is formulated as a mixed integer linear programming-based optimization model which considers emergency operation decisions in IDCs and restoration decisions in power distribution systems, and can minimize the utility loss of IDCs and other loads during the restoration process. Since the original form of the proposed method may face some problems in practical application, such as confidential information sharing and long computing time, a decoupling method is proposed to convert the integrated model into several sequential parts which are operated by power distribution systems or IDCs independently, so that the confidential information sharing issue is solved, and the computing time is significantly reduced. The proposed restoration method is tested on the IEEE 123-Bus Feeder with multiple IDCs to illustrate its feasibility and efficiency. | - |
dc.language | eng | - |
dc.relation.ispartof | IEEE Transactions on Smart Grid | - |
dc.subject | Power distribution | - |
dc.subject | Power supplies | - |
dc.subject | Computational modeling | - |
dc.subject | Critical infrastructure | - |
dc.subject | Optimization | - |
dc.title | Restoration of Power Distribution Systems With Multiple Data Centers as Critical Loads | - |
dc.type | Article | - |
dc.identifier.email | Lei, S: leishunbo@eee.hku.hk | - |
dc.identifier.email | Hou, Y: yhhou@hku.hk | - |
dc.identifier.authority | Hou, Y=rp00069 | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1109/TSG.2018.2880255 | - |
dc.identifier.scopus | eid_2-s2.0-85056309417 | - |
dc.identifier.hkuros | 306597 | - |
dc.identifier.hkuros | 316685 | - |
dc.identifier.volume | 10 | - |
dc.identifier.issue | 5 | - |
dc.identifier.spage | 5294 | - |
dc.identifier.epage | 5307 | - |
dc.identifier.eissn | 1949-3061 | - |
dc.identifier.isi | WOS:000482623500053 | - |
dc.identifier.issnl | 1949-3053 | - |