Article: A General Design Procedure for Multi-Parallel Modular Grid-Tied Inverters System to Prevent Common and Interactive Instability
Title | A General Design Procedure for Multi-Parallel Modular Grid-Tied Inverters System to Prevent Common and Interactive Instability |
---|---|
Authors | |
Keywords | Inverters Power system stability Stability criteria Damping Resonant frequency |
Issue Date | 2019 |
Publisher | Institute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=63 |
Citation | IEEE Transactions on Power Electronics, 2019, v. 34 n. 7, p. 6025-6030 How to Cite? |
Abstract | Based on the equivalent circuit model, the interactions of multi-parallel modular grid-tied inverters and their coupling effect with grid impedance are analyzed in this letter. The analysis shows that interactive instability could happen in the inverter system even when identical inverters have been used. However, if the control and circuit parameters are designed systematically, the system can be exempted from both common and interactive instability. The outcome of this research provides a practical general design paradigm for modular grid-tied inverters with inductor-capacitor-inductor (LCL) filters which can be used in the parallel operation with unknown number of modules. Experimental results are provided for verification. |
Persistent Identifier | http://hdl.handle.net/10722/278150 |
ISSN | 2023 Impact Factor: 6.6 2023 SCImago Journal Rankings: 3.644 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | CHEN, T | - |
dc.contributor.author | Lee, CK | - |
dc.contributor.author | Hui, SYR | - |
dc.date.accessioned | 2019-10-04T08:08:27Z | - |
dc.date.available | 2019-10-04T08:08:27Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | IEEE Transactions on Power Electronics, 2019, v. 34 n. 7, p. 6025-6030 | - |
dc.identifier.issn | 0885-8993 | - |
dc.identifier.uri | http://hdl.handle.net/10722/278150 | - |
dc.description.abstract | Based on the equivalent circuit model, the interactions of multi-parallel modular grid-tied inverters and their coupling effect with grid impedance are analyzed in this letter. The analysis shows that interactive instability could happen in the inverter system even when identical inverters have been used. However, if the control and circuit parameters are designed systematically, the system can be exempted from both common and interactive instability. The outcome of this research provides a practical general design paradigm for modular grid-tied inverters with inductor-capacitor-inductor (LCL) filters which can be used in the parallel operation with unknown number of modules. Experimental results are provided for verification. | - |
dc.language | eng | - |
dc.publisher | Institute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=63 | - |
dc.relation.ispartof | IEEE Transactions on Power Electronics | - |
dc.rights | IEEE Transactions on Power Electronics. Copyright © Institute of Electrical and Electronics Engineers. | - |
dc.rights | ©20xx IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. | - |
dc.subject | Inverters | - |
dc.subject | Power system stability | - |
dc.subject | Stability criteria | - |
dc.subject | Damping | - |
dc.subject | Resonant frequency | - |
dc.title | A General Design Procedure for Multi-Parallel Modular Grid-Tied Inverters System to Prevent Common and Interactive Instability | - |
dc.type | Article | - |
dc.identifier.email | Lee, CK: cklee@eee.hku.hk | - |
dc.identifier.email | Hui, SYR: ronhui@eee.hku.hk | - |
dc.identifier.authority | Lee, CK=rp01580 | - |
dc.identifier.authority | Hui, SYR=rp01510 | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1109/TPEL.2019.2890842 | - |
dc.identifier.scopus | eid_2-s2.0-85065429782 | - |
dc.identifier.hkuros | 306273 | - |
dc.identifier.volume | 34 | - |
dc.identifier.issue | 7 | - |
dc.identifier.spage | 6025 | - |
dc.identifier.epage | 6030 | - |
dc.identifier.isi | WOS:000469278900006 | - |
dc.publisher.place | United States | - |
dc.identifier.issnl | 0885-8993 | - |