File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Optical coherence tomography with balanced signal strength across the depth for pearl inspection

TitleOptical coherence tomography with balanced signal strength across the depth for pearl inspection
Authors
Issue Date2020
PublisherOptical Society of America: Open Access Journals. The Journal's web site is located at https://www.osapublishing.org/osac
Citation
OSA Continuum, 2020, v. 3 n. 7, p. 1739-1750 How to Cite?
AbstractOptical coherence tomography (OCT) relies on the reflection of light from structures in different layers to interferometrically reconstruct the volumetric image of the sample. However, light returned from multiple layers suffers from imbalanced attenuation owing to the optical path difference and inhomogeneous tissue absorption. We report an optimization algorithm to improve signal strength in deep tissue for swept-source (SS)-OCT imaging. This algorithm utilizes the attenuation coefficient of consecutive layers within the sample and combines them to compensate for the signal intensity loss from deep tissue. We stacked 170-µm thick cover slides as a standard sample for benchmark testing. The optimized OCT image provides a 30% increase in signal intensity in the deep structure compared with the conventional images. We applied this method for pearl inspection, whose layered structure demonstrates a great application for our optimized OCT imaging. In contrast to X-ray micro-CT scan and scanning electron microscope (SEM) imaging modalities, the optimized OCT imaging provides great potential for pearl quality inspection. The proposed improvement algorithm for SS-OCT could also be applied to diverse biomedical imaging scenarios, including label-free tissue imaging.
Persistent Identifierhttp://hdl.handle.net/10722/289699
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorMAO, H-
dc.contributor.authorFENG, P-
dc.contributor.authorRen, YX-
dc.contributor.authorKang, J-
dc.contributor.authorTsia, KK-
dc.contributor.authorYan, WT-
dc.contributor.authorWong, KKY-
dc.date.accessioned2020-10-22T08:16:11Z-
dc.date.available2020-10-22T08:16:11Z-
dc.date.issued2020-
dc.identifier.citationOSA Continuum, 2020, v. 3 n. 7, p. 1739-1750-
dc.identifier.urihttp://hdl.handle.net/10722/289699-
dc.description.abstractOptical coherence tomography (OCT) relies on the reflection of light from structures in different layers to interferometrically reconstruct the volumetric image of the sample. However, light returned from multiple layers suffers from imbalanced attenuation owing to the optical path difference and inhomogeneous tissue absorption. We report an optimization algorithm to improve signal strength in deep tissue for swept-source (SS)-OCT imaging. This algorithm utilizes the attenuation coefficient of consecutive layers within the sample and combines them to compensate for the signal intensity loss from deep tissue. We stacked 170-µm thick cover slides as a standard sample for benchmark testing. The optimized OCT image provides a 30% increase in signal intensity in the deep structure compared with the conventional images. We applied this method for pearl inspection, whose layered structure demonstrates a great application for our optimized OCT imaging. In contrast to X-ray micro-CT scan and scanning electron microscope (SEM) imaging modalities, the optimized OCT imaging provides great potential for pearl quality inspection. The proposed improvement algorithm for SS-OCT could also be applied to diverse biomedical imaging scenarios, including label-free tissue imaging.-
dc.languageeng-
dc.publisherOptical Society of America: Open Access Journals. The Journal's web site is located at https://www.osapublishing.org/osac-
dc.relation.ispartofOSA Continuum-
dc.rightsOSA Continuum. Copyright © Optical Society of America: Open Access Journals.-
dc.rights© 2020 [Optical Society of America]. Users may use, reuse, and build upon the article, or use the article for text or data mining, so long as such uses are for non-commercial purposes and appropriate attribution is maintained. All other rights are reserved.-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.titleOptical coherence tomography with balanced signal strength across the depth for pearl inspection-
dc.typeArticle-
dc.identifier.emailTsia, KK: tsia@hku.hk-
dc.identifier.emailWong, KKY: kywong@eee.hku.hk-
dc.identifier.authorityTsia, KK=rp01389-
dc.identifier.authorityWong, KKY=rp00189-
dc.description.naturepublished_or_final_version-
dc.identifier.doi10.1364/OSAC.394157-
dc.identifier.scopuseid_2-s2.0-85105689701-
dc.identifier.hkuros316691-
dc.identifier.volume3-
dc.identifier.issue7-
dc.identifier.spage1739-
dc.identifier.epage1750-
dc.identifier.eissn2578-7519-
dc.identifier.isiWOS:000550236700011-
dc.publisher.placeUnited States-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats