File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Strengthening Design of RC Columns with Direct Fastening Steel Jackets

TitleStrengthening Design of RC Columns with Direct Fastening Steel Jackets
Authors
KeywordsRC columns
strengthening
direct fastening
steel jackets
design procedure
Issue Date2021
PublisherMDPI AG. The Journal's web site is located at http://www.mdpi.com/journal/applsci
Citation
Applied Sciences, 2021, v. 11 n. 8, p. article no. 3649 How to Cite?
AbstractFor non-seismically designed columns with insufficient strength and flexural stiffness, intense inter-story drift can be incurred during a strong earthquake event, potentially leading to the collapse of the entire building. Existing strengthening methods mainly focus on enhancing axial or flexural strength but not the flexural stiffness of columns. In response, a novel direct fastening steel jackets that can increase both flexural strength and stiffness is introduced. This novel strengthening method features straightforward installation and swift strengthening as direct fastening is used to connect steel plates together to form a steel jacketed column. This new connection method can quickly and stably connect two steel components together by driving high strength fasteners into them. In this paper, the design procedure of RC columns strengthened with this novel strengthening method is originally proposed, which includes five steps: (1) estimating lateral load capacity of damaged RC columns; (2) determining connection spacing of steel jacket; (3) estimating the lateral load capacity of strengthened RC column; (4) evaluating the axial load ratio (ALR) of strengthened RC columns; and (5) estimating effective stiffness of strengthened RC columns. Lastly, an example is presented to illustrate the application of the proposed design procedure.
Persistent Identifierhttp://hdl.handle.net/10722/301464
ISSN
2021 Impact Factor: 2.838
2020 SCImago Journal Rankings: 0.435
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorSHAN, Z-
dc.contributor.authorCHEN, L-
dc.contributor.authorLIANG, K-
dc.contributor.authorSu, RKL-
dc.contributor.authorXu, Z-
dc.date.accessioned2021-07-27T08:11:28Z-
dc.date.available2021-07-27T08:11:28Z-
dc.date.issued2021-
dc.identifier.citationApplied Sciences, 2021, v. 11 n. 8, p. article no. 3649-
dc.identifier.issn2076-3417-
dc.identifier.urihttp://hdl.handle.net/10722/301464-
dc.description.abstractFor non-seismically designed columns with insufficient strength and flexural stiffness, intense inter-story drift can be incurred during a strong earthquake event, potentially leading to the collapse of the entire building. Existing strengthening methods mainly focus on enhancing axial or flexural strength but not the flexural stiffness of columns. In response, a novel direct fastening steel jackets that can increase both flexural strength and stiffness is introduced. This novel strengthening method features straightforward installation and swift strengthening as direct fastening is used to connect steel plates together to form a steel jacketed column. This new connection method can quickly and stably connect two steel components together by driving high strength fasteners into them. In this paper, the design procedure of RC columns strengthened with this novel strengthening method is originally proposed, which includes five steps: (1) estimating lateral load capacity of damaged RC columns; (2) determining connection spacing of steel jacket; (3) estimating the lateral load capacity of strengthened RC column; (4) evaluating the axial load ratio (ALR) of strengthened RC columns; and (5) estimating effective stiffness of strengthened RC columns. Lastly, an example is presented to illustrate the application of the proposed design procedure.-
dc.languageeng-
dc.publisherMDPI AG. The Journal's web site is located at http://www.mdpi.com/journal/applsci-
dc.relation.ispartofApplied Sciences-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectRC columns-
dc.subjectstrengthening-
dc.subjectdirect fastening-
dc.subjectsteel jackets-
dc.subjectdesign procedure-
dc.titleStrengthening Design of RC Columns with Direct Fastening Steel Jackets-
dc.typeArticle-
dc.identifier.emailSu, RKL: klsu@hkucc.hku.hk-
dc.identifier.authoritySu, RKL=rp00072-
dc.description.naturepublished_or_final_version-
dc.identifier.doi10.3390/app11083649-
dc.identifier.scopuseid_2-s2.0-85104929027-
dc.identifier.hkuros323660-
dc.identifier.volume11-
dc.identifier.issue8-
dc.identifier.spagearticle no. 3649-
dc.identifier.epagearticle no. 3649-
dc.identifier.isiWOS:000643990200001-
dc.publisher.placeSwitzerland-

Export via OAI-PMH Interface in XML Formats


OR