Article: Thermometry of photosensitive and optically induced electrokinetics chips
Title | Thermometry of photosensitive and optically induced electrokinetics chips |
---|---|
Authors | |
Issue Date | 2018 |
Citation | Microsystems and Nanoengineering, 2018, v. 4, n. 1, article no. 26 How to Cite? |
Abstract | Optically induced electrokinetics (OEK)-based technologies, which integrate the high-resolution dynamic addressability of optical tweezers and the high-throughput capability of electrokinetic forces, have been widely used to manipulate, assemble, and separate biological and non-biological entities in parallel on scales ranging from micrometers to nanometers. However, simultaneously introducing optical and electrical energy into an OEK chip may induce a problematic temperature increase, which poses the potential risk of exceeding physiological conditions and thus inducing variations in cell behavior or activity or even irreversible cell damage during bio-manipulation. Here, we systematically measure the temperature distribution and changes in an OEK chip arising from the projected images and applied alternating current (AC) voltage using an infrared camera. We have found that the average temperature of a projected area is influenced by the light color, total illumination area, ratio of lighted regions to the total controlled areas, and amplitude of the AC voltage. As an example, optically induced thermocapillary flow is triggered by the light image-induced temperature gradient on a photosensitive substrate to realize fluidic hydrogel patterning. Our studies show that the projected light pattern needs to be properly designed to satisfy specific application requirements, especially for applications related to cell manipulation and assembly. |
Persistent Identifier | http://hdl.handle.net/10722/325418 |
PubMed Central ID | |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wang, Feifei | - |
dc.contributor.author | Liu, Lianqing | - |
dc.contributor.author | Li, Gongxin | - |
dc.contributor.author | Li, Pan | - |
dc.contributor.author | Wen, Yangdong | - |
dc.contributor.author | Zhang, Guanglie | - |
dc.contributor.author | Wang, Yuechao | - |
dc.contributor.author | Lee, Gwo Bin | - |
dc.contributor.author | Li, Wen Jung | - |
dc.date.accessioned | 2023-02-27T07:33:07Z | - |
dc.date.available | 2023-02-27T07:33:07Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Microsystems and Nanoengineering, 2018, v. 4, n. 1, article no. 26 | - |
dc.identifier.uri | http://hdl.handle.net/10722/325418 | - |
dc.description.abstract | Optically induced electrokinetics (OEK)-based technologies, which integrate the high-resolution dynamic addressability of optical tweezers and the high-throughput capability of electrokinetic forces, have been widely used to manipulate, assemble, and separate biological and non-biological entities in parallel on scales ranging from micrometers to nanometers. However, simultaneously introducing optical and electrical energy into an OEK chip may induce a problematic temperature increase, which poses the potential risk of exceeding physiological conditions and thus inducing variations in cell behavior or activity or even irreversible cell damage during bio-manipulation. Here, we systematically measure the temperature distribution and changes in an OEK chip arising from the projected images and applied alternating current (AC) voltage using an infrared camera. We have found that the average temperature of a projected area is influenced by the light color, total illumination area, ratio of lighted regions to the total controlled areas, and amplitude of the AC voltage. As an example, optically induced thermocapillary flow is triggered by the light image-induced temperature gradient on a photosensitive substrate to realize fluidic hydrogel patterning. Our studies show that the projected light pattern needs to be properly designed to satisfy specific application requirements, especially for applications related to cell manipulation and assembly. | - |
dc.language | eng | - |
dc.relation.ispartof | Microsystems and Nanoengineering | - |
dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
dc.title | Thermometry of photosensitive and optically induced electrokinetics chips | - |
dc.type | Article | - |
dc.description.nature | published_or_final_version | - |
dc.identifier.doi | 10.1038/s41378-018-0029-y | - |
dc.identifier.pmid | 31057914 | - |
dc.identifier.pmcid | PMC6220187 | - |
dc.identifier.scopus | eid_2-s2.0-85056246568 | - |
dc.identifier.volume | 4 | - |
dc.identifier.issue | 1 | - |
dc.identifier.spage | article no. 26 | - |
dc.identifier.epage | article no. 26 | - |
dc.identifier.eissn | 2055-7434 | - |
dc.identifier.isi | WOS:000442809500001 | - |