File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: On the corrosion rate measurement of reinforcing steel in chloride induced macrocell corrosion

TitleOn the corrosion rate measurement of reinforcing steel in chloride induced macrocell corrosion
Authors
Issue Date1-Nov-2022
PublisherElsevier
Citation
Cement and Concrete Composites, 2022, v. 134, p. 104775 How to Cite?
AbstractThis study investigates the corrosion rate measurement of reinforcing steel under chloride-induced macrocell corrosion in reinforced concrete (RC). The corrosion rates of RC columns with different cover thicknesses and chloride concentrations were evaluated using different techniques and cathode over anode ratios. The applicability of the Stern-Geary equation on the macrocell corrosion of RC was studied. The results show that the corrosion rate of highly corroding steel can be underestimated by an order of magnitude by the linear polarisation resistance method due to a failure to compensate for diffusion resistance. The effect of macrocell corrosion on the measurement of polarisation resistance is moderate with a relative error less than 2. The galvanostatic polarisation technique can eliminate the influence of diffusion resistance and therefore reliably measure polarisation resistance. A B value of 52 mV is recommended under macrocell corrosion.
Persistent Identifierhttp://hdl.handle.net/10722/328318
ISSN
2022 Impact Factor: 10.5
2020 SCImago Journal Rankings: 2.896

 

DC FieldValueLanguage
dc.contributor.authorChen, LJ-
dc.contributor.authorSu, RKL-
dc.date.accessioned2023-06-28T04:42:06Z-
dc.date.available2023-06-28T04:42:06Z-
dc.date.issued2022-11-01-
dc.identifier.citationCement and Concrete Composites, 2022, v. 134, p. 104775-
dc.identifier.issn0958-9465-
dc.identifier.urihttp://hdl.handle.net/10722/328318-
dc.description.abstractThis study investigates the corrosion rate measurement of reinforcing steel under chloride-induced macrocell corrosion in reinforced concrete (RC). The corrosion rates of RC columns with different cover thicknesses and chloride concentrations were evaluated using different techniques and cathode over anode ratios. The applicability of the Stern-Geary equation on the macrocell corrosion of RC was studied. The results show that the corrosion rate of highly corroding steel can be underestimated by an order of magnitude by the linear polarisation resistance method due to a failure to compensate for diffusion resistance. The effect of macrocell corrosion on the measurement of polarisation resistance is moderate with a relative error less than 2. The galvanostatic polarisation technique can eliminate the influence of diffusion resistance and therefore reliably measure polarisation resistance. A B value of 52 mV is recommended under macrocell corrosion.-
dc.languageeng-
dc.publisherElsevier-
dc.relation.ispartofCement and Concrete Composites-
dc.titleOn the corrosion rate measurement of reinforcing steel in chloride induced macrocell corrosion-