File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)

Article: Co-existence of airborne SARS-CoV-2 infection and non-infection in three connected zones of a restaurant

TitleCo-existence of airborne SARS-CoV-2 infection and non-infection in three connected zones of a restaurant
Authors
KeywordsAirborne transmission
COVID-19
FCU filtration
Minimum ventilation requirement
Quanta generation rate
Issue Date5-Dec-2024
PublisherElsevier
Citation
Journal of Hazardous Materials, 2024, v. 480 How to Cite?
Abstract

The lack of knowledge on quanta generation rates presents a major obstacle to specifying the minimum ventilation required to prevent airborne infections. The expected largest quanta generation rate of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by a super-spreader remains unknown. Here we investigated a SARS-CoV-2 outbreak during lunch in a restaurant using epidemiological, whole-genome sequencing and environmental analyses. Both tracer gas and fine particles were used in field experiments to quantify aerosol dispersion and removal across three interconnected zones: Zone A, Zone B and Zone C. All 21 secondary patron infections occurred in Zone B. This unique infection feature and measured dilution flow rates allowed us to estimate the largest reported quanta generation rates to date, ranging from 1724 to 1968 quanta/h. These rates were sufficiently high to cause a high attack rate in Zone B but did not cause infections in Zones A and C, likely due to sufficient dilution and insignificant contaminated airflow from Zone B, respectively. Our finding of the largest quanta generation rate so far suggests that avoiding secondary infection by dilution alone in the presence of a super-emitter might not be possible in typical air-conditioned buildings and other prevention strategies need to be developed.


Persistent Identifierhttp://hdl.handle.net/10722/355342
ISSN
2023 Impact Factor: 12.2
2023 SCImago Journal Rankings: 2.950

 

DC FieldValueLanguage
dc.contributor.authorJia, Wei-
dc.contributor.authorWang, Qun-
dc.contributor.authorLung, David Christopher-
dc.contributor.authorChan, Pak To-
dc.contributor.authorWang, Peihua-
dc.contributor.authorDung, Edwin Chung Hin-
dc.contributor.authorDidik, Tiffany-
dc.contributor.authorChoi, Garnet Kwan Yue-
dc.contributor.authorTse, Herman-
dc.contributor.authorWu, Yijie-
dc.contributor.authorMiao, Te-
dc.contributor.authorChen, Wenzhao-
dc.contributor.authorQian, Hua-
dc.contributor.authorXue, Fan-
dc.contributor.authorLi, Yuguo-
dc.date.accessioned2025-04-04T00:35:14Z-
dc.date.available2025-04-04T00:35:14Z-
dc.date.issued2024-12-05-
dc.identifier.citationJournal of Hazardous Materials, 2024, v. 480-
dc.identifier.issn0304-3894-
dc.identifier.urihttp://hdl.handle.net/10722/355342-
dc.description.abstract<p>The lack of knowledge on quanta generation rates presents a major obstacle to specifying the minimum ventilation required to prevent airborne infections. The expected largest quanta generation rate of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by a super-spreader remains unknown. Here we investigated a SARS-CoV-2 outbreak during lunch in a restaurant using epidemiological, whole-genome sequencing and environmental analyses. Both tracer gas and fine particles were used in field experiments to quantify aerosol dispersion and removal across three interconnected zones: Zone A, Zone B and Zone C. All 21 secondary patron infections occurred in Zone B. This unique infection feature and measured dilution flow rates allowed us to estimate the largest reported quanta generation rates to date, ranging from 1724 to 1968 quanta/h. These rates were sufficiently high to cause a high attack rate in Zone B but did not cause infections in Zones A and C, likely due to sufficient dilution and insignificant contaminated airflow from Zone B, respectively. Our finding of the largest quanta generation rate so far suggests that avoiding secondary infection by dilution alone in the presence of a super-emitter might not be possible in typical air-conditioned buildings and other prevention strategies need to be developed.</p>-
dc.languageeng-
dc.publisherElsevier-
dc.relation.ispartofJournal of Hazardous Materials-
dc.subjectAirborne transmission-
dc.subjectCOVID-19-
dc.subjectFCU filtration-
dc.subjectMinimum ventilation requirement-
dc.subjectQuanta generation rate-
dc.titleCo-existence of airborne SARS-CoV-2 infection and non-infection in three connected zones of a restaurant-
dc.typeArticle-
dc.identifier.doi10.1016/j.jhazmat.2024.136388-
dc.identifier.scopuseid_2-s2.0-85208105302-
dc.identifier.volume480-
dc.identifier.eissn1873-3336-
dc.identifier.issnl0304-3894-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats