Conference Paper: SU‐FF‐I‐68: False Positive Analysis of Functional MRI During Simulated Deep Brain Stimulation

TitleSU‐FF‐I‐68: False Positive Analysis of Functional MRI During Simulated Deep Brain Stimulation
Authors
Issue Date2006
Citation
Medical Physics, 2006, v. 33, n. 6, p. 2012 How to Cite?
AbstractPurpose: Recent studies showed that MRI can be safely performed on patients with deep brain stimulation (DBS) device in place when the stimulator is turned off. By interleaving the DBS and echo‐planar imaging (EPI) acquisition, functional MRI (fMRI) may be a useful tool for understanding the mechanism of DBS as well as helping the localization of electrodes. This study aimed to investigate the possible false positive activations due to the limited time interval between the end of DBS and the start of EPI acquisition. Method and Materials: The study was performed using a 1.5‐T Philips MRI scanner with a DBS electrode (Medtronic, Minneapolis MN) positioned in the center of a gel‐filled phantom. The experimental run consisted of alternative 5 stimulation‐off and 4 stimulation‐on blocks (the stimulator was turned on for 2 seconds immediately after each readout). The control run consisted of total stimulation‐off blocks. A single‐shot GE EPI (TR/TE = 6000ms/60ms, FOV = 192mm, matrix = 64×64, SW = 3mm) was used, with 10/30 slices per measurement in for long/short inter‐scan waiting times (ISWT). Data were analyzed using SPM2. False activation and deactivation volumes were computed at different statistical thresholds. Results: For both activation and deactivation, no false positive voxels were detected for all conditions at corrected p<0.05 or uncorrected p<0.001. For uncorrected p>0.001, number of false activated/deactivated voxels increased with p‐value increased. No increased trend was observed with the experimental conditions as compared to the control conditions. Similar trends were observed when comparing activation vs. deactivation and long vs. short ISWT. Conclusion: An ISWT of 2230 ms (TR= 6s, 30‐slice acquisition) was found to be sufficient for placing a 2‐s DBS without increased false positive detections of activation/deactivation. A statistical threshold of p<0.001 or tighter is recommended for fMRI involving the similar amount of total voxels as this study. © 2006, American Association of Physicists in Medicine. All rights reserved.
Persistent Identifierhttp://hdl.handle.net/10722/363257
ISSN
2023 Impact Factor: 3.2
2023 SCImago Journal Rankings: 1.052

 

DC FieldValueLanguage
dc.contributor.authorLiu, H. L.-
dc.contributor.authorHuang, C. M.-
dc.contributor.authorLim, S. N.-
dc.contributor.authorKuan, W. C.-
dc.contributor.authorChen, H. M.-
dc.contributor.authorWu, T.-
dc.contributor.authorHsu, Y. Y.-
dc.date.accessioned2025-10-10T07:45:34Z-
dc.date.available2025-10-10T07:45:34Z-
dc.date.issued2006-
dc.identifier.citationMedical Physics, 2006, v. 33, n. 6, p. 2012-
dc.identifier.issn0094-2405-
dc.identifier.urihttp://hdl.handle.net/10722/363257-
dc.description.abstractPurpose: Recent studies showed that MRI can be safely performed on patients with deep brain stimulation (DBS) device in place when the stimulator is turned off. By interleaving the DBS and echo‐planar imaging (EPI) acquisition, functional MRI (fMRI) may be a useful tool for understanding the mechanism of DBS as well as helping the localization of electrodes. This study aimed to investigate the possible false positive activations due to the limited time interval between the end of DBS and the start of EPI acquisition. Method and Materials: The study was performed using a 1.5‐T Philips MRI scanner with a DBS electrode (Medtronic, Minneapolis MN) positioned in the center of a gel‐filled phantom. The experimental run consisted of alternative 5 stimulation‐off and 4 stimulation‐on blocks (the stimulator was turned on for 2 seconds immediately after each readout). The control run consisted of total stimulation‐off blocks. A single‐shot GE EPI (TR/TE = 6000ms/60ms, FOV = 192mm, matrix = 64×64, SW = 3mm) was used, with 10/30 slices per measurement in for long/short inter‐scan waiting times (ISWT). Data were analyzed using SPM2. False activation and deactivation volumes were computed at different statistical thresholds. Results: For both activation and deactivation, no false positive voxels were detected for all conditions at corrected p<0.05 or uncorrected p<0.001. For uncorrected p>0.001, number of false activated/deactivated voxels increased with p‐value increased. No increased trend was observed with the experimental conditions as compared to the control conditions. Similar trends were observed when comparing activation vs. deactivation and long vs. short ISWT. Conclusion: An ISWT of 2230 ms (TR= 6s, 30‐slice acquisition) was found to be sufficient for placing a 2‐s DBS without increased false positive detections of activation/deactivation. A statistical threshold of p<0.001 or tighter is recommended for fMRI involving the similar amount of total voxels as this study. © 2006, American Association of Physicists in Medicine. All rights reserved.-
dc.languageeng-
dc.relation.ispartofMedical Physics-
dc.titleSU‐FF‐I‐68: False Positive Analysis of Functional MRI During Simulated Deep Brain Stimulation-
dc.typeConference_Paper-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1118/1.2240748-
dc.identifier.scopuseid_2-s2.0-85024783381-
dc.identifier.volume33-
dc.identifier.issue6-
dc.identifier.spage2012-
dc.identifier.epage-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats