File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Vessel extraction under non-uniform illumination: A level set approach

TitleVessel extraction under non-uniform illumination: A level set approach
Authors
KeywordsActive contours
Level set method
Local contrast enhancement
Medical image analysis
Nonuniform illumination
Vessel extraction
Issue Date2008
PublisherIEEE.
Citation
Ieee Transactions On Biomedical Engineering, 2008, v. 55 n. 1, p. 358-360 How to Cite?
AbstractVessel extraction is one of the critical tasks in clinical practice. This communication presents a new approach for vessel extraction using a level-set-based active contour by defining a novel local term that takes local image contrast into account. The proposed model not only preserves the performance of the existing models on blurry images, but also overcomes their inability to handle nonuniform illumination. The efficacy of the approach is demonstrated with experiments involving both synthetic images and clinical angiograms. © 2006 IEEE.
Persistent Identifierhttp://hdl.handle.net/10722/57473
ISSN
2023 Impact Factor: 4.4
2023 SCImago Journal Rankings: 1.239
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorSum, KWen_HK
dc.contributor.authorCheung, PYSen_HK
dc.date.accessioned2010-04-12T01:37:33Z-
dc.date.available2010-04-12T01:37:33Z-
dc.date.issued2008en_HK
dc.identifier.citationIeee Transactions On Biomedical Engineering, 2008, v. 55 n. 1, p. 358-360en_HK
dc.identifier.issn0018-9294en_HK
dc.identifier.urihttp://hdl.handle.net/10722/57473-
dc.description.abstractVessel extraction is one of the critical tasks in clinical practice. This communication presents a new approach for vessel extraction using a level-set-based active contour by defining a novel local term that takes local image contrast into account. The proposed model not only preserves the performance of the existing models on blurry images, but also overcomes their inability to handle nonuniform illumination. The efficacy of the approach is demonstrated with experiments involving both synthetic images and clinical angiograms. © 2006 IEEE.en_HK
dc.languageengen_HK
dc.publisherIEEE.en_HK
dc.relation.ispartofIEEE Transactions on Biomedical Engineeringen_HK
dc.rights©2007 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.-
dc.subjectActive contoursen_HK
dc.subjectLevel set methoden_HK
dc.subjectLocal contrast enhancementen_HK
dc.subjectMedical image analysisen_HK
dc.subjectNonuniform illuminationen_HK
dc.subjectVessel extractionen_HK
dc.subject.meshAlgorithmsen_HK
dc.subject.meshAngiography - methodsen_HK
dc.subject.meshImaging, Three-Dimensional - methodsen_HK
dc.subject.meshInformation Storage and Retrieval - methodsen_HK
dc.subject.meshLighting - methodsen_HK
dc.titleVessel extraction under non-uniform illumination: A level set approachen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0018-9294&volume=55&issue=1&spage=358&epage=360&date=2008&atitle=Vessel+extraction+under+non-uniform+illumination:+a+level+set+approachen_HK
dc.identifier.emailCheung, PYS:paul.cheung@hku.hken_HK
dc.identifier.authorityCheung, PYS=rp00077en_HK
dc.description.naturepublished_or_final_versionen_HK
dc.identifier.doi10.1109/TBME.2007.896587en_HK
dc.identifier.pmid18232383-
dc.identifier.scopuseid_2-s2.0-37349048294en_HK
dc.identifier.hkuros152464-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-37349048294&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume55en_HK
dc.identifier.issue1en_HK
dc.identifier.spage358en_HK
dc.identifier.epage360en_HK
dc.identifier.isiWOS:000251908300043-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridSum, KW=16040209400en_HK
dc.identifier.scopusauthoridCheung, PYS=7202595335en_HK
dc.identifier.issnl0018-9294-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats