File Download
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1080/10556780802367171
- Scopus: eid_2-s2.0-52149118436
- WOS: WOS:000259314500005
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Extreme diffusion values for non-Gaussian diffusions
Title | Extreme diffusion values for non-Gaussian diffusions |
---|---|
Authors | |
Keywords | Diffusion Gaussian noise (electronic) Imaging techniques Magnetic resonance imaging Numerical methods |
Issue Date | 2008 |
Publisher | Taylor & Francis Ltd. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/10556788.asp |
Citation | Optimization Methods and Software, 2008, v. 23, p. 703-716 How to Cite? |
Abstract | A new magnetic resonance imaging (MRI) model, called diffusion kurtosis imaging (DKI), was recently proposed, to characterize the non-Gaussian diffusion behaviour in tissues. DKI involves a fourth-order three-dimensional tensor and a second-order three-dimensional tensor. Similar to those in the diffusion tensor imaging (DTI) model, the extreme diffusion values and extreme directions associated to this tensor pair play important roles in DKI. In this paper, we study the properties of the extreme values and directions associated to such tensor pairs. We also present a numerical method and its preliminary computational results. |
Persistent Identifier | http://hdl.handle.net/10722/58732 |
ISSN | 2023 Impact Factor: 1.4 2023 SCImago Journal Rankings: 1.001 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Han, D | en_HK |
dc.contributor.author | Qi, L | en_HK |
dc.contributor.author | Wu, EX | en_HK |
dc.date.accessioned | 2010-05-31T03:35:56Z | - |
dc.date.available | 2010-05-31T03:35:56Z | - |
dc.date.issued | 2008 | en_HK |
dc.identifier.citation | Optimization Methods and Software, 2008, v. 23, p. 703-716 | en_HK |
dc.identifier.issn | 1055-6788 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/58732 | - |
dc.description.abstract | A new magnetic resonance imaging (MRI) model, called diffusion kurtosis imaging (DKI), was recently proposed, to characterize the non-Gaussian diffusion behaviour in tissues. DKI involves a fourth-order three-dimensional tensor and a second-order three-dimensional tensor. Similar to those in the diffusion tensor imaging (DTI) model, the extreme diffusion values and extreme directions associated to this tensor pair play important roles in DKI. In this paper, we study the properties of the extreme values and directions associated to such tensor pairs. We also present a numerical method and its preliminary computational results. | - |
dc.language | eng | en_HK |
dc.publisher | Taylor & Francis Ltd. The Journal's web site is located at http://www.tandf.co.uk/journals/titles/10556788.asp | en_HK |
dc.relation.ispartof | Optimization Methods and Software | en_HK |
dc.subject | Diffusion | - |
dc.subject | Gaussian noise (electronic) | - |
dc.subject | Imaging techniques | - |
dc.subject | Magnetic resonance imaging | - |
dc.subject | Numerical methods | - |
dc.title | Extreme diffusion values for non-Gaussian diffusions | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1055-6788&volume=23&spage=703&epage=716&date=2008&atitle=Extreme+diffusion+values+for+non-Gaussian+diffusions | en_HK |
dc.identifier.email | Wu, EX: ewu@eee.hku.hk | en_HK |
dc.identifier.authority | Wu, EX=rp00193 | en_HK |
dc.description.nature | postprint | - |
dc.identifier.doi | 10.1080/10556780802367171 | - |
dc.identifier.scopus | eid_2-s2.0-52149118436 | - |
dc.identifier.hkuros | 161915 | en_HK |
dc.identifier.isi | WOS:000259314500005 | - |
dc.identifier.citeulike | 3347162 | - |
dc.identifier.issnl | 1026-7670 | - |