File Download
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1136/bjo.2008.147306
- Scopus: eid_2-s2.0-60849106254
- PMID: 19174403
- WOS: WOS:000262833900028
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Visualising vitreous through modified trans-scleral illumination by maximising the Tyndall effect
Title | Visualising vitreous through modified trans-scleral illumination by maximising the Tyndall effect |
---|---|
Authors | |
Issue Date | 2009 |
Publisher | BMJ Publishing Group. The Journal's web site is located at http://bjo.bmjjournals.com/ |
Citation | British Journal Of Ophthalmology, 2009, v. 93 n. 2, p. 268-270 How to Cite? |
Abstract | Background: A new technique for visualisation of the vitreous base is described. It uses a standard lightpipe for scleral indentation and transillumination. Visualisation of the vitreous using low light levels can be achieved by enhancing the Tyndall effect. Discussion: Perfluorocarbon liquid (PFCL) is used to confine the aqueous environment to the anterior vitreous cavity and triamcinolone is added to increase light scatter. The technique clearly differentiates vitreous from PFCL and infusion fluid, and facilitates trimming of the vitreous base, draining of subretinal fluid and air/fluid exchange. |
Persistent Identifier | http://hdl.handle.net/10722/60907 |
ISSN | 2023 Impact Factor: 3.7 2023 SCImago Journal Rankings: 1.862 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Veckeneer, M | en_HK |
dc.contributor.author | Wong, D | en_HK |
dc.date.accessioned | 2010-05-31T04:21:35Z | - |
dc.date.available | 2010-05-31T04:21:35Z | - |
dc.date.issued | 2009 | en_HK |
dc.identifier.citation | British Journal Of Ophthalmology, 2009, v. 93 n. 2, p. 268-270 | en_HK |
dc.identifier.issn | 0007-1161 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/60907 | - |
dc.description.abstract | Background: A new technique for visualisation of the vitreous base is described. It uses a standard lightpipe for scleral indentation and transillumination. Visualisation of the vitreous using low light levels can be achieved by enhancing the Tyndall effect. Discussion: Perfluorocarbon liquid (PFCL) is used to confine the aqueous environment to the anterior vitreous cavity and triamcinolone is added to increase light scatter. The technique clearly differentiates vitreous from PFCL and infusion fluid, and facilitates trimming of the vitreous base, draining of subretinal fluid and air/fluid exchange. | en_HK |
dc.language | eng | en_HK |
dc.publisher | BMJ Publishing Group. The Journal's web site is located at http://bjo.bmjjournals.com/ | en_HK |
dc.relation.ispartof | British Journal of Ophthalmology | en_HK |
dc.rights | British Journal of Ophthalmology. Copyright © BMJ Publishing Group. | en_HK |
dc.subject.mesh | Retinal Detachment - surgery | - |
dc.subject.mesh | Transillumination - instrumentation - methods | - |
dc.subject.mesh | Triamcinolone | - |
dc.subject.mesh | Vitrectomy - instrumentation - methods | - |
dc.subject.mesh | Vitreous Body | - |
dc.title | Visualising vitreous through modified trans-scleral illumination by maximising the Tyndall effect | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0007-1161&volume=93&issue=2&spage=268&epage=270&date=2009&atitle=Visualising+vitreous+through+modified+trans-scleral+illumination+by+maximising+the+Tyndall+effect | en_HK |
dc.identifier.email | Wong, D: shdwong@hku.hk | en_HK |
dc.identifier.authority | Wong, D=rp00516 | en_HK |
dc.description.nature | published_or_final_version | - |
dc.identifier.doi | 10.1136/bjo.2008.147306 | en_HK |
dc.identifier.pmid | 19174403 | - |
dc.identifier.scopus | eid_2-s2.0-60849106254 | en_HK |
dc.identifier.hkuros | 154796 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-60849106254&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 93 | en_HK |
dc.identifier.issue | 2 | en_HK |
dc.identifier.spage | 268 | en_HK |
dc.identifier.epage | 270 | en_HK |
dc.identifier.isi | WOS:000262833900028 | - |
dc.publisher.place | United Kingdom | en_HK |
dc.identifier.scopusauthorid | Veckeneer, M=6602817503 | en_HK |
dc.identifier.scopusauthorid | Wong, D=7401536078 | en_HK |
dc.identifier.issnl | 0007-1161 | - |