File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.jmr.2007.03.003
- Scopus: eid_2-s2.0-34249948683
- PMID: 17433744
- WOS: WOS:000247490500025
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: A realization of digital wireless transmission for MRI signals based on 802.11b
Title | A realization of digital wireless transmission for MRI signals based on 802.11b |
---|---|
Authors | |
Keywords | Coil array Digital wireless transmission IEEE 802.11 Magnetic resonance imaging (MRI) |
Issue Date | 2007 |
Publisher | Academic Press. The Journal's web site is located at http://www.elsevier.com/locate/yjmre |
Citation | Journal Of Magnetic Resonance, 2007, v. 186 n. 2, p. 358-363 How to Cite? |
Abstract | In this paper, a digital wireless transmission system based on 802.11b standard for magnetic resonance imaging (MRI) application is designed and built for the first time to eliminate the interference aroused by coil array cables. The analysis shows that the wireless receiver has a very high sensitivity to detect MRI signals. The modulation technique of differential quadrature phase shift keyed (DQPSK) can be applied to MRI data transmission with rate of 2 Mbps and bandwidth of 2 MHz. The bench test verifies that this wireless link has a dynamic range over 86 dB supporting up to 3T MRI system data transmission. The 2D spin echo imaging of phantom is performed and the SNR of the image obtained by the wireless transmission can be comparable with that got by the coaxial cables. © 2007 Elsevier Inc. All rights reserved. |
Persistent Identifier | http://hdl.handle.net/10722/73956 |
ISSN | 2023 Impact Factor: 2.0 2023 SCImago Journal Rankings: 0.593 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wei, J | en_HK |
dc.contributor.author | Liu, Z | en_HK |
dc.contributor.author | Chai, Z | en_HK |
dc.contributor.author | Yuan, J | en_HK |
dc.contributor.author | Lian, J | en_HK |
dc.contributor.author | Shen, GX | en_HK |
dc.date.accessioned | 2010-09-06T06:56:24Z | - |
dc.date.available | 2010-09-06T06:56:24Z | - |
dc.date.issued | 2007 | en_HK |
dc.identifier.citation | Journal Of Magnetic Resonance, 2007, v. 186 n. 2, p. 358-363 | en_HK |
dc.identifier.issn | 1090-7807 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/73956 | - |
dc.description.abstract | In this paper, a digital wireless transmission system based on 802.11b standard for magnetic resonance imaging (MRI) application is designed and built for the first time to eliminate the interference aroused by coil array cables. The analysis shows that the wireless receiver has a very high sensitivity to detect MRI signals. The modulation technique of differential quadrature phase shift keyed (DQPSK) can be applied to MRI data transmission with rate of 2 Mbps and bandwidth of 2 MHz. The bench test verifies that this wireless link has a dynamic range over 86 dB supporting up to 3T MRI system data transmission. The 2D spin echo imaging of phantom is performed and the SNR of the image obtained by the wireless transmission can be comparable with that got by the coaxial cables. © 2007 Elsevier Inc. All rights reserved. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Academic Press. The Journal's web site is located at http://www.elsevier.com/locate/yjmre | en_HK |
dc.relation.ispartof | Journal of Magnetic Resonance | en_HK |
dc.subject | Coil array | en_HK |
dc.subject | Digital wireless transmission | en_HK |
dc.subject | IEEE 802.11 | en_HK |
dc.subject | Magnetic resonance imaging (MRI) | en_HK |
dc.title | A realization of digital wireless transmission for MRI signals based on 802.11b | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1090-7807&volume=186&spage=358&epage=363&date=2007&atitle=A+Realization+of+Digital+Wireless+Transmission+for+MRI+Signals+Based+on+802.11b | en_HK |
dc.identifier.email | Shen, GX: gxshen@eee.hku.hk | en_HK |
dc.identifier.authority | Shen, GX=rp00166 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.jmr.2007.03.003 | en_HK |
dc.identifier.pmid | 17433744 | - |
dc.identifier.scopus | eid_2-s2.0-34249948683 | en_HK |
dc.identifier.hkuros | 137402 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-34249948683&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 186 | en_HK |
dc.identifier.issue | 2 | en_HK |
dc.identifier.spage | 358 | en_HK |
dc.identifier.epage | 363 | en_HK |
dc.identifier.isi | WOS:000247490500025 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Wei, J=12780903400 | en_HK |
dc.identifier.scopusauthorid | Liu, Z=13607694400 | en_HK |
dc.identifier.scopusauthorid | Chai, Z=36955694400 | en_HK |
dc.identifier.scopusauthorid | Yuan, J=35788305600 | en_HK |
dc.identifier.scopusauthorid | Lian, J=16432870100 | en_HK |
dc.identifier.scopusauthorid | Shen, GX=7401967224 | en_HK |
dc.identifier.issnl | 1090-7807 | - |