Article: Interconnecting L/C components for decoupling and its application to low-field open MRI array
Title | Interconnecting L/C components for decoupling and its application to low-field open MRI array |
---|---|
Authors | |
Keywords | Decoupling circuit Low-field open MRI Mutual coupling Phased array RF coil |
Issue Date | 2007 |
Publisher | John Wiley & Sons, Inc.. The Journal's web site is located at http://www.interscience.wiley.com/jpages/1043-7347:1/ |
Citation | Concepts in Magnetic Resonance. Part B: Magnetic Resonance Engineering, 2007, v. 31B n. 2, p. 116-126 How to Cite? |
Abstract | Interconnecting L/C components are often applied to decouple the array elements for parallel imaging. Although it has been recognized that interconnecting capacitors and inductors can both be employed for decoupling, quantitative study of this decoupling technique has not yet been presented. In this study, a theoretical analysis for the interconnecting L/C decoupling circuit is provided. The analysis reveals that the required decoupling capacitance decreases with the resonant frequency, whereas the decoupling inductance is independent of the frequency. The inductive decoupling scheme is applied in the design of a four-channel knee coil for 0.5 T open MRI with vertical magnetic field. Experimental results show that good isolations (−19 dB ∼ −45 dB) between coil elements can be achieved and only 5% ∼ 11% degeneration of Q is caused by this decoupling method. |
Persistent Identifier | http://hdl.handle.net/10722/74054 |
ISSN | 2023 Impact Factor: 0.9 2020 SCImago Journal Rankings: 0.286 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wu, B | en_HK |
dc.contributor.author | Qu, P | en_HK |
dc.contributor.author | Wang, C | en_HK |
dc.contributor.author | Yuan, J | en_HK |
dc.contributor.author | Shen, GG | en_HK |
dc.date.accessioned | 2010-09-06T06:57:21Z | - |
dc.date.available | 2010-09-06T06:57:21Z | - |
dc.date.issued | 2007 | en_HK |
dc.identifier.citation | Concepts in Magnetic Resonance. Part B: Magnetic Resonance Engineering, 2007, v. 31B n. 2, p. 116-126 | en_HK |
dc.identifier.issn | 1552-5031 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/74054 | - |
dc.description.abstract | Interconnecting L/C components are often applied to decouple the array elements for parallel imaging. Although it has been recognized that interconnecting capacitors and inductors can both be employed for decoupling, quantitative study of this decoupling technique has not yet been presented. In this study, a theoretical analysis for the interconnecting L/C decoupling circuit is provided. The analysis reveals that the required decoupling capacitance decreases with the resonant frequency, whereas the decoupling inductance is independent of the frequency. The inductive decoupling scheme is applied in the design of a four-channel knee coil for 0.5 T open MRI with vertical magnetic field. Experimental results show that good isolations (−19 dB ∼ −45 dB) between coil elements can be achieved and only 5% ∼ 11% degeneration of Q is caused by this decoupling method. | - |
dc.language | eng | en_HK |
dc.publisher | John Wiley & Sons, Inc.. The Journal's web site is located at http://www.interscience.wiley.com/jpages/1043-7347:1/ | en_HK |
dc.relation.ispartof | Concepts in Magnetic Resonance. Part B: Magnetic Resonance Engineering | en_HK |
dc.subject | Decoupling circuit | - |
dc.subject | Low-field open MRI | - |
dc.subject | Mutual coupling | - |
dc.subject | Phased array | - |
dc.subject | RF coil | - |
dc.title | Interconnecting L/C components for decoupling and its application to low-field open MRI array | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1552-5031&volume=31B Issue 2&spage=116&epage=126&date=2007&atitle=Interconnecting+L/C+Components+for+Decoupling+and+Its+Application+to+the+Low-field+Open+MRI+Array | en_HK |
dc.identifier.email | Shen, GG: gxshen@eee.hku.hk | en_HK |
dc.identifier.authority | Shen, GG=rp00166 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1002/cmr.b.20087 | - |
dc.identifier.scopus | eid_2-s2.0-34248393114 | - |
dc.identifier.hkuros | 132658 | en_HK |
dc.identifier.isi | WOS:000245882700005 | - |
dc.identifier.issnl | 1552-5031 | - |