File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: A prospective randomized trial comparing the use of the flexible gastroscope versus the bronchoscope in the management of foreign body ingestion

TitleA prospective randomized trial comparing the use of the flexible gastroscope versus the bronchoscope in the management of foreign body ingestion
Authors
Issue Date1998
PublisherMosby, Inc. The Journal's web site is located at http://www.elsevier.com/locate/gie
Citation
Gastrointestinal Endoscopy, 1998, v. 47 n. 1, p. 23-27 How to Cite?
AbstractBackground: Foreign body ingestion is a common clinical problem in Hong Kong. Some recent reports have proposed the use of flexible nasoendoscopy for foreign body retrieval. The present study is a prospective randomized trial on the use of the flexible gastroscope and bronchoscope in the management of foreign body ingestion. Methods: Two hundred sixteen patients older than 11 years were prospectively randomized to flexible endoscopic examination using either the gastroscope (108 patients) or the bronchoscope (108 patients). The duration of the procedure was noted. Patients were asked to assess their overall tolerance to the procedure on a scale of 1 (well tolerated) to 10 (unacceptable). Results: A foreign body was retrieved in 68 patients (31.5%). There was no difference between the two groups in the foreign body retrieval rate, type of foreign body retrieved, duration of procedure, and tolerance level. In the group managed with the bronchoscope, however, three patients required the additional use of the gastroscope for foreign body retrieval at (for one patient) or below (for two patients) the cricopharyngeus. The patient's tolerance level was related only to the duration of procedure (rho = 0.386; p < 0.001). Conclusion: The use of the flexible gastroscope is recommended because of its efficacy, safety, and tolerability.
Persistent Identifierhttp://hdl.handle.net/10722/83963
ISSN
2021 Impact Factor: 10.396
2020 SCImago Journal Rankings: 2.365
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorChu, KMen_HK
dc.contributor.authorChoi, HKen_HK
dc.contributor.authorTuen, HHen_HK
dc.contributor.authorLaw, SYKen_HK
dc.contributor.authorBranicki, FJen_HK
dc.contributor.authorWong, Jen_HK
dc.date.accessioned2010-09-06T08:47:18Z-
dc.date.available2010-09-06T08:47:18Z-
dc.date.issued1998en_HK
dc.identifier.citationGastrointestinal Endoscopy, 1998, v. 47 n. 1, p. 23-27en_HK
dc.identifier.issn0016-5107en_HK
dc.identifier.urihttp://hdl.handle.net/10722/83963-
dc.description.abstractBackground: Foreign body ingestion is a common clinical problem in Hong Kong. Some recent reports have proposed the use of flexible nasoendoscopy for foreign body retrieval. The present study is a prospective randomized trial on the use of the flexible gastroscope and bronchoscope in the management of foreign body ingestion. Methods: Two hundred sixteen patients older than 11 years were prospectively randomized to flexible endoscopic examination using either the gastroscope (108 patients) or the bronchoscope (108 patients). The duration of the procedure was noted. Patients were asked to assess their overall tolerance to the procedure on a scale of 1 (well tolerated) to 10 (unacceptable). Results: A foreign body was retrieved in 68 patients (31.5%). There was no difference between the two groups in the foreign body retrieval rate, type of foreign body retrieved, duration of procedure, and tolerance level. In the group managed with the bronchoscope, however, three patients required the additional use of the gastroscope for foreign body retrieval at (for one patient) or below (for two patients) the cricopharyngeus. The patient's tolerance level was related only to the duration of procedure (rho = 0.386; p < 0.001). Conclusion: The use of the flexible gastroscope is recommended because of its efficacy, safety, and tolerability.en_HK
dc.languageengen_HK
dc.publisherMosby, Inc. The Journal's web site is located at http://www.elsevier.com/locate/gieen_HK
dc.relation.ispartofGastrointestinal Endoscopyen_HK
dc.rightsGastrointestinal Endoscopy. Copyright © Mosby, Inc.en_HK
dc.titleA prospective randomized trial comparing the use of the flexible gastroscope versus the bronchoscope in the management of foreign body ingestionen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0016-5107&volume=47&spage=23&epage=27&date=1998&atitle=A+prospective+randomized+trial+comparing+the+use+of+the+flexible+gastroscope+versus+the+bronchoscope+in+the+management+of+foreign+body+ingestionen_HK
dc.identifier.emailChu, KM: chukm@hkucc.hku.hken_HK
dc.identifier.emailLaw, SYK: slaw@hku.hken_HK
dc.identifier.emailWong, J: jwong@hkucc.hku.hken_HK
dc.identifier.authorityChu, KM=rp00435en_HK
dc.identifier.authorityLaw, SYK=rp00437en_HK
dc.identifier.authorityWong, J=rp00322en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/S0016-5107(98)70294-9en_HK
dc.identifier.pmid9468419-
dc.identifier.scopuseid_2-s2.0-0031884665en_HK
dc.identifier.hkuros32003en_HK
dc.identifier.volume47en_HK
dc.identifier.issue1en_HK
dc.identifier.spage23en_HK
dc.identifier.epage27en_HK
dc.identifier.isiWOS:000071560000004-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridChu, KM=7402453538en_HK
dc.identifier.scopusauthoridChoi, HK=7404339913en_HK
dc.identifier.scopusauthoridTuen, HH=6602991320en_HK
dc.identifier.scopusauthoridLaw, SYK=7202241293en_HK
dc.identifier.scopusauthoridBranicki, FJ=7003617514en_HK
dc.identifier.scopusauthoridWong, J=8049324500en_HK
dc.identifier.issnl0016-5107-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats