File Download
  Links for fulltext
     (May Require Subscription)
  • Find via Find It@HKUL
Supplementary

Conference Paper: Comparison of RF Penetration and G-factor of Different Coil Arrays for Parallel Imaging

TitleComparison of RF Penetration and G-factor of Different Coil Arrays for Parallel Imaging
Authors
Issue Date2004
PublisherThe International Society for Magnetic Resonance in Medicine (ISMRM)
Citation
The International Society for Magnetic Resonance in Medicine (ISMRM) 12th Scientific Meeting & Exhibition, Kyoto, Japan, 15-21 May 2004. In Proceedings of the International Society for Magnetic Resonance in Medicine (ISMRM), 2004, v. 11, p. 1603 How to Cite?
AbstractGeometry factor and RF penetration of different kinds of coil arrays for parallel imaging were evaluated by simulations using MATLAB and XFDTD software. The results show that the coil arrays with loop structure are superior to the planar strip arrays in terms of g-map and RF penetration. The overlapped loop array has better RF penetration, while the non-overlapped one has a lower noise level in parallel imaging.
Persistent Identifierhttp://hdl.handle.net/10722/99300
ISSN

 

DC FieldValueLanguage
dc.contributor.authorWei, Jen_HK
dc.contributor.authorQu, Pen_HK
dc.contributor.authorShen, GGen_HK
dc.date.accessioned2010-09-25T18:24:04Z-
dc.date.available2010-09-25T18:24:04Z-
dc.date.issued2004en_HK
dc.identifier.citationThe International Society for Magnetic Resonance in Medicine (ISMRM) 12th Scientific Meeting & Exhibition, Kyoto, Japan, 15-21 May 2004. In Proceedings of the International Society for Magnetic Resonance in Medicine (ISMRM), 2004, v. 11, p. 1603en_HK
dc.identifier.issn1545-4436-
dc.identifier.urihttp://hdl.handle.net/10722/99300-
dc.description.abstractGeometry factor and RF penetration of different kinds of coil arrays for parallel imaging were evaluated by simulations using MATLAB and XFDTD software. The results show that the coil arrays with loop structure are superior to the planar strip arrays in terms of g-map and RF penetration. The overlapped loop array has better RF penetration, while the non-overlapped one has a lower noise level in parallel imaging.-
dc.languageengen_HK
dc.publisherThe International Society for Magnetic Resonance in Medicine (ISMRM)en_HK
dc.relation.ispartofProceedings of the International Society for Magnetic Resonance in Medicine (ISMRM)en_HK
dc.titleComparison of RF Penetration and G-factor of Different Coil Arrays for Parallel Imagingen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailShen, GG: gxshen@eee.hku.hken_HK
dc.identifier.authorityShen, GG=rp00166en_HK
dc.description.naturepublished_or_final_version-
dc.identifier.hkuros91400en_HK
dc.identifier.volume11en_HK