Conference Paper: Optimal Utilization of Acquired k-space points for GRAPPA reconstruction

TitleOptimal Utilization of Acquired k-space points for GRAPPA reconstruction
Authors
Issue Date2005
PublisherInternational Society for Magnetic Resonance in Medicine.
Citation
International Society for Magnetic Resonance in Medicine 13th Scientific Meeting & Exhibition, Miami, FL, 7-13 May 2005, p. 2667 How to Cite?
AbstractThe generalized approach to parallel MRI has indicated that the utilization of acquired k-space points for GRAPPA reconstruction can be more flexible, including the points in frequency encoding direction. To investigate the optimal utilization of acquired k-space points in GRAPPA, the neighbor GRAPPA which incorporates several neighbor points to estimate each missing point is compared with the conventional GRAPPA by simulations and experiments. It is discovered that the optimal reconstruction scheme should depend on the geometry of the receive coil array and the orientation of FOV.
Persistent Identifierhttp://hdl.handle.net/10722/99362

 

DC FieldValueLanguage
dc.contributor.authorQu, Pen_HK
dc.contributor.authorWu, Ben_HK
dc.contributor.authorWang, Cen_HK
dc.contributor.authorShen, GGen_HK
dc.date.accessioned2010-09-25T18:26:50Z-
dc.date.available2010-09-25T18:26:50Z-
dc.date.issued2005en_HK
dc.identifier.citationInternational Society for Magnetic Resonance in Medicine 13th Scientific Meeting & Exhibition, Miami, FL, 7-13 May 2005, p. 2667en_HK
dc.identifier.urihttp://hdl.handle.net/10722/99362-
dc.description.abstractThe generalized approach to parallel MRI has indicated that the utilization of acquired k-space points for GRAPPA reconstruction can be more flexible, including the points in frequency encoding direction. To investigate the optimal utilization of acquired k-space points in GRAPPA, the neighbor GRAPPA which incorporates several neighbor points to estimate each missing point is compared with the conventional GRAPPA by simulations and experiments. It is discovered that the optimal reconstruction scheme should depend on the geometry of the receive coil array and the orientation of FOV.-
dc.languageengen_HK
dc.publisherInternational Society for Magnetic Resonance in Medicine.en_HK
dc.relation.ispartofInternational Society for Magnetic Resonance in Medicine Scientific Meeting & Exhibitionen_HK
dc.titleOptimal Utilization of Acquired k-space points for GRAPPA reconstructionen_HK
dc.typeConference_Paperen_HK
dc.identifier.emailShen, GG: gxshen@eee.hku.hken_HK
dc.identifier.authorityShen, GG=rp00166en_HK
dc.description.naturepublished_or_final_version-
dc.identifier.hkuros104537en_HK
dc.identifier.volume, v. 1en_HK
dc.identifier.spage2667en_HK