File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/TBCAS.2018.2810182
- Scopus: eid_2-s2.0-85044071718
- PMID: 29877827
- WOS: WOS:000434466000019
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: A Wearable Detector for Simultaneous Finger Joint Motion Measurement
Title | A Wearable Detector for Simultaneous Finger Joint Motion Measurement |
---|---|
Authors | |
Keywords | Finger joint motion Hand goniometry Sensor array Stretchable glove |
Issue Date | 2018 |
Publisher | Institute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=4156126 |
Citation | IEEE Transactions on Biomedical Circuits and Systems, 2018, v. 12 n. 3, p. 644-654 How to Cite? |
Abstract | This paper presents a wearable and stretchable detector for simultaneous finger joint motion measurement, providing the feasible technical solutions to solve the problems existing in the current devices. The sensor array installed in the detector consists of 14 custom-made bending sensors and an inertial measurement unit with high accuracy. The glove support for a sensor array, which is made of three silicone materials with different elasticity, not only overcomes the drawbacks of cloth support, but also addresses the compatibility between the stretch substrate and the inelastic sensing components. Besides, two-section electrical connection avoids the problems caused by the external wires in traditional solutions to enhance the durability of glove. The experiment results indicated that the wearable detector offers a good user experience by exerting a small force on fingers. The device also shows a strong durability as it worked properly after tens of thousands of bending. The measurement tests on a single sensor demonstrated that two kinds of sensors are both with high accuracy. Besides, the hand goniometric system has an excellent performance in terms of hand motion detection. The measurement error of the device in subjects with different hand sizes is within a reasonable range. The good properties of the sensory detector allow it to be applied in clinical applications. |
Persistent Identifier | http://hdl.handle.net/10722/254722 |
ISSN | 2023 Impact Factor: 3.8 2023 SCImago Journal Rankings: 1.462 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Li, X | - |
dc.contributor.author | Wen, R | - |
dc.contributor.author | Shen, Z | - |
dc.contributor.author | Wang, Z | - |
dc.contributor.author | Luk, KDK | - |
dc.contributor.author | Hu, Y | - |
dc.date.accessioned | 2018-06-21T01:05:27Z | - |
dc.date.available | 2018-06-21T01:05:27Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | IEEE Transactions on Biomedical Circuits and Systems, 2018, v. 12 n. 3, p. 644-654 | - |
dc.identifier.issn | 1932-4545 | - |
dc.identifier.uri | http://hdl.handle.net/10722/254722 | - |
dc.description.abstract | This paper presents a wearable and stretchable detector for simultaneous finger joint motion measurement, providing the feasible technical solutions to solve the problems existing in the current devices. The sensor array installed in the detector consists of 14 custom-made bending sensors and an inertial measurement unit with high accuracy. The glove support for a sensor array, which is made of three silicone materials with different elasticity, not only overcomes the drawbacks of cloth support, but also addresses the compatibility between the stretch substrate and the inelastic sensing components. Besides, two-section electrical connection avoids the problems caused by the external wires in traditional solutions to enhance the durability of glove. The experiment results indicated that the wearable detector offers a good user experience by exerting a small force on fingers. The device also shows a strong durability as it worked properly after tens of thousands of bending. The measurement tests on a single sensor demonstrated that two kinds of sensors are both with high accuracy. Besides, the hand goniometric system has an excellent performance in terms of hand motion detection. The measurement error of the device in subjects with different hand sizes is within a reasonable range. The good properties of the sensory detector allow it to be applied in clinical applications. | - |
dc.language | eng | - |
dc.publisher | Institute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=4156126 | - |
dc.relation.ispartof | IEEE Transactions on Biomedical Circuits and Systems | - |
dc.rights | IEEE Transactions on Biomedical Circuits and Systems. Copyright © Institute of Electrical and Electronics Engineers. | - |
dc.subject | Finger joint motion | - |
dc.subject | Hand goniometry | - |
dc.subject | Sensor array | - |
dc.subject | Stretchable glove | - |
dc.title | A Wearable Detector for Simultaneous Finger Joint Motion Measurement | - |
dc.type | Article | - |
dc.identifier.email | Wen, R: rwwen@hku.hk | - |
dc.identifier.email | Wang, Z: zwangski@hku.hk | - |
dc.identifier.email | Luk, KDK: hrmoldk@hku.hk | - |
dc.identifier.email | Hu, Y: yhud@hku.hk | - |
dc.identifier.authority | Wang, Z=rp01915 | - |
dc.identifier.authority | Luk, KDK=rp00333 | - |
dc.identifier.authority | Hu, Y=rp00432 | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1109/TBCAS.2018.2810182 | - |
dc.identifier.pmid | 29877827 | - |
dc.identifier.scopus | eid_2-s2.0-85044071718 | - |
dc.identifier.hkuros | 285381 | - |
dc.identifier.volume | 12 | - |
dc.identifier.issue | 3 | - |
dc.identifier.spage | 644 | - |
dc.identifier.epage | 654 | - |
dc.identifier.isi | WOS:000434466000019 | - |
dc.publisher.place | United States | - |
dc.identifier.issnl | 1932-4545 | - |