Article: Adaptive High-Bandwidth Digitally Controlled Buck Converter with Improved Line and Load Transient Response
Title | Adaptive High-Bandwidth Digitally Controlled Buck Converter with Improved Line and Load Transient Response |
---|---|
Authors | |
Issue Date | 2014 |
Publisher | The Institution of Engineering and Technology. The Journal's web site is located at http://digital-library.theiet.org/IET-PEL |
Citation | IET Power Electronics, 2014, v. 7 n. 3, p. 515-526 How to Cite? |
Abstract | Digitally controlled switching converter suffers from bandwidth limitation because of the additional phase delay in the digital feedback control loop. In order to overcome the bandwidth limitation without using a high sampling rate, this paper presents an adaptive third-order digital controller for regulating a voltage-mode buck converter with a modest 2x oversampling ratio. The phase lag due to the ADC conversion time delay is virtually compensated by providing an early estimation of the error voltage for the next sampling time instant, enabling a higher unity-gain bandwidth without compromising stability. An additional pair of low-frequency pole and zero in the third-order controller increases the low-frequency gain, resulting in faster settling time and smaller output voltage deviation during line transient. Both simulation and experimental results demonstrate that the proposed adaptive third-order controller reduces the settling time by 50% in response to a 1 V line transient and 30% in response to a 600 mA load transient, compared to the baseline static second-order controller. The fastest settling time is measured to be around 11.70 s, surpassing the transient performance of conventional digital controllers and approaching that of the state-of-the-art analog-based controllers. |
Persistent Identifier | http://hdl.handle.net/10722/215298 |
ISSN | 2023 Impact Factor: 1.7 2023 SCImago Journal Rankings: 0.736 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, ATL | - |
dc.contributor.author | Sin, JKO | - |
dc.contributor.author | Chan, PCH | - |
dc.date.accessioned | 2015-08-21T13:21:09Z | - |
dc.date.available | 2015-08-21T13:21:09Z | - |
dc.date.issued | 2014 | - |
dc.identifier.citation | IET Power Electronics, 2014, v. 7 n. 3, p. 515-526 | - |
dc.identifier.issn | 1755-4535 | - |
dc.identifier.uri | http://hdl.handle.net/10722/215298 | - |
dc.description.abstract | Digitally controlled switching converter suffers from bandwidth limitation because of the additional phase delay in the digital feedback control loop. In order to overcome the bandwidth limitation without using a high sampling rate, this paper presents an adaptive third-order digital controller for regulating a voltage-mode buck converter with a modest 2x oversampling ratio. The phase lag due to the ADC conversion time delay is virtually compensated by providing an early estimation of the error voltage for the next sampling time instant, enabling a higher unity-gain bandwidth without compromising stability. An additional pair of low-frequency pole and zero in the third-order controller increases the low-frequency gain, resulting in faster settling time and smaller output voltage deviation during line transient. Both simulation and experimental results demonstrate that the proposed adaptive third-order controller reduces the settling time by 50% in response to a 1 V line transient and 30% in response to a 600 mA load transient, compared to the baseline static second-order controller. The fastest settling time is measured to be around 11.70 s, surpassing the transient performance of conventional digital controllers and approaching that of the state-of-the-art analog-based controllers. | - |
dc.language | eng | - |
dc.publisher | The Institution of Engineering and Technology. The Journal's web site is located at http://digital-library.theiet.org/IET-PEL | - |
dc.relation.ispartof | IET Power Electronics | - |
dc.rights | This paper is a postprint of a paper submitted to and accepted for publication in IET Power Electronics and is subject to IET copyright. The copy of record is available at IET Digital Library | - |
dc.title | Adaptive High-Bandwidth Digitally Controlled Buck Converter with Improved Line and Load Transient Response | - |
dc.type | Article | - |
dc.identifier.email | Lee, ATL: tlalee@hku.hk | - |
dc.description.nature | postprint | - |
dc.identifier.doi | 10.1049/iet-pel.2013.0263 | - |
dc.identifier.scopus | eid_2-s2.0-84896983507 | - |
dc.identifier.hkuros | 244386 | - |
dc.identifier.volume | 7 | - |
dc.identifier.issue | 3 | - |
dc.identifier.spage | 515 | - |
dc.identifier.epage | 526 | - |
dc.identifier.isi | WOS:000333407600006 | - |
dc.publisher.place | United Kingdom | - |
dc.identifier.issnl | 1755-4535 | - |